METHODS. We reviewed videos of DR resuscitations; identified whether intubation was attempted; and, when attempted, whether intubation was attempted by a resident, a fellow, or a consultant. We defined the duration of an intubation attempt as the time from the introduction of the laryngoscope blade to the mouth to its removal, regardless of whether an ETT was introduced. We determined the time from removal of the laryngoscope to the clinicians' decision as to whether the intubation was successful and noted the basis on which this decision was made (clinical assessment, flow signals, or exhaled carbon dioxide [ETCO2] detection). We determined success according to clinical signs in all cases and used flow signals that were obtained during ventilation via the ETT or ETCO2 when available. When neither was available, the chest radiograph on admission to the NICU was reviewed. For infants who were monitored with pulse oximetry, we determined their HR and SpO2 before the intubation attempt. We then determined whether either or both fell by
10% during the attempt and, if so, at what time it occurred.
RESULTS. We reviewed 122 video recordings in which orotracheal intubation was attempted 60 times in 31 infants. We secondarily verified ETT position using flow signals, ETCO2, or chest radiographs after 94% of attempts in which an ETT was introduced. Thirty-seven (62%) attempts were successful. Success rates and mean (SD) time to intubate successfully by group were as follows: residents: 24%, 49 seconds (13 seconds); fellows: 78%, 32 seconds (13 seconds); and consultants: 86%, 25 seconds (17 seconds). Of the 23 unsuccessful attempts, 13 were abandoned without an attempt to pass an ETT and 10 were placed incorrectly. The time to determine ETT position in the DR was longer when clinical assessment alone was used. Infants who were monitored with oximetry deteriorated during nearly half of the intubation attempts. Deterioration seemed more likely when HR and SpO2 were low before the attempt.
CONCLUSIONS. Intubation attempts often are unsuccessful, and successful attempts frequently take >30 seconds. Greater experience is associated with greater success rates and shorter duration of successful attempts. Flow signals and ETCO2 may be useful in determining ETT position more quickly than clinical assessment alone. Infants frequently deteriorate during intubation attempts. Improved monitoring of infants who are resuscitated in the DR is desirable.
Key Words: infant newborn resuscitation positive pressure respiration endotracheal intubation
Abbreviations: ETTendotracheal tube NRPNeonatal Resuscitation Program DRdelivery room SpO2oxygen saturation HRheart rate ETCO2exhaled carbon dioxide
International consensus statements1 and guidelines on neonatal resuscitation2,3 advise that infants with inadequate respiration and/or bradycardia at birth be given positive pressure ventilation with a manual ventilation device with a face mask or endotracheal tube (ETT). Endotracheal intubation of newborn infants is a mandatory competence for basic training in pediatrics in many countries.4,5 The Neonatal Resuscitation Program (NRP) recommends that intubation attempts be limited to 20 seconds.2
A United Kingdom study of the care of preterm infants and its effect on their survival identified difficulties with intubation and the level of experience of staff present as the most common concerns about neonatal resuscitation.6 In a US study of pediatric residents, none met the authors' definition of procedural competence for intubation (successful at first or second attempt
80% of the time) over a 2-year period.7 An additional US study of delivery room (DR) intubations that were performed mainly by residents and fellows found that few were successful within 20 seconds and that more infants were intubated between 20 and 30 seconds without apparent adverse effect.8 Another study from the same center reported that just over half of all intubation attempts that were performed by junior doctors were successful and that residents there currently have inadequate opportunity to become proficient.9
There is little information on the success rates or duration of intubation attempts of more experienced operators. Also, although adverse effects of endotracheal intubation in the intensive care setting have been described,10 there is little information on the effects of intubation attempts on infants' oxygen saturations (SpO2) and heart rate (HR) as determined by pulse oximetry in the DR. Using video recordings, we wished to determine (1) the success rates and duration of intubation attempts during neonatal resuscitation at our hospital, (2) whether the success rates and duration of successful attempts by staff varied with different levels of experience, (3) the time taken to identify ETT position after attempted intubation, and (4) the frequency with which infants deteriorated during intubation attempts and the time at which this occurred.
| METHODS |
|---|
|
|
|---|
5000 deliveries per year. Approximately 450 infants are admitted to the NICU per year, 100 to 110 of whom have a gestational age of <28 weeks or birth weight of <1 kg. We do not have advanced neonatal nurse practitioners or respiratory therapists; thus, all infants are intubated by medical staff: residents, fellows, or consultants. In general, the residents are pediatric trainees whose first exposure to neonatal medicine or intensive care occurs during their 6-month rotation at our hospital. Usually, they have no previous experience with intubation. The fellows have variable but at least 18 months' experience of neonatal intensive care and thus intubation. Consultants at our hospital have a range of 5 to 35 years' experience in neonatal medicine and extensive intubation experience.
Resuscitation Practice
All staff who attend deliveries at our hospital complete an in-house resuscitation training program based on international consensus statements1 and the NRP.2 The Neopuff Infant Resuscitator (Fisher & Paykel, Auckland, New Zealand) t-piece and the Laerdal Infant Resuscitator (Laerdal, Oakleigh Victoria, Australia) self-inflating bag are the manual ventilation devices used at our hospital. Peak inflating and positive end-expiratory pressures are set at 30 and 5 cm H2O, respectively, on the Neopuff. In the DR, ETT position is judged from clinical signs as recommended in international consensus statements1; on occasion, an exhaled carbon dioxide (ETCO2) detector (Pedi-Cap Nellcor Puritan Bennet, Pleasanton, CA) is used for secondary confirmation. A time limit for intubation attempts is not enforced rigidly at our institution. Infants who are intubated in our DR are transferred to the NICU, where they have a chest radiograph to confirm ETT position.
Resuscitation Studies
Since January 2004, we have recorded DR resuscitations at our hospital with the endorsement of our Human Research and Ethics Committee. When available, a member of the investigating team attended deliveries for which the need for resuscitation was anticipated and made detailed recordings. When time allowed before delivery, the parents were approached and their permission was sought to record the resuscitation. When time did not allow, the resuscitation was recorded and the parents were approached as soon as practicable thereafter. Their permission then was sought to view the recordings and to use them for data extraction and educational purposes.
We recorded resuscitations using a digital video camera that was mounted above the resuscitation cot and positioned to acquire a clear view of the infant and resuscitative interventions. Sound was audible from these recordings. The sensor of a Masimo Radical (Masimo Corp, Irvine, CA) pulse oximeter was placed on the infants' right hand or wrist as soon as practicable after delivery. The oximeter was set to capture HR and SpO2 with maximal sensitivity and average data over 2-second intervals.
Many of the infants who were videotaped had pulmonary mechanics measured during positive pressure ventilation using the Florian Respiratory Monitor (Acutronic, Zug, Switzerland). This monitor measures pressures in the respiratory circuit directly and uses a sensor placed between the ventilation device and the ETT to measure gas flow. These data were recorded and analyzed using a laptop computer with Spectra software (Grove Medical, London, United Kingdom), a program designed specifically for the recording and analysis of respiratory signals (see Fig 1). Although not usually available to the resuscitation team in the DR, these signals were used occasionally to determine ETT position during the resuscitation. They were used to determine ETT position retrospectively for this study.
|
For infants who were monitored with pulse oximetry during the procedure, we determined the times of life at which the sensor was applied and oximetry data were available. We determined whether preoxygenation was given before the attempt and the HR and SpO2 before and after the attempt. We considered the infants' condition to have deteriorated when their HR and/or SpO2 fell by
10% during the procedure and noted the time at which this occurred.
Statistical Analysis
Mean (SD) duration of intubation attempts by different grades of doctors were compared using 1-way analysis of variance and test for linearity. Proportions of successful intubations by different grades of doctors were compared using
2 test and linear-by-linear association. SPSS version 12.0.1 (SPSS Inc, Chicago IL) was used for analysis.
| RESULTS |
|---|
|
|
|---|
|
Successful Attempts
Overall, 37 (62%) intubation attempts were successful. In the DR, ETT position was determined by clinical assessment alone after 26 attempts; flow signals (see Fig 1B) and ETCO2 were used in addition after 7 and 4 attempts, respectively. Twenty-seven attempts were subsequently verified as successful using flow signals. For the remaining 6 infants who had neither a flow sensor nor an ETCO2 detector in the circuit in the DR, review of the chest radiographs on admission to the NICU confirmed correct placement of the ETT.
The rates of success and duration of intubation attempts overall and by group are shown in Table 2. The time taken to intubate successfully differed between grades of doctors (P < .01, analysis of variance), with more senior doctors intubating more rapidly (P < .01, test of linear trend; Table 2, Fig 3). Similarly, success rates differed between grades of doctors (P < .001, Pearson
2), with senior doctors more successful (P < .001, linear-by-linear trend; Table 2). The 2 shortest successful attempts were 8 seconds. Ten (17%) attempts were successful within 20 seconds, an additional 12 (20%) were successful between 20 and 29 seconds, and the remaining 15 (25%) successful intubations took >30 seconds. The longest successful attempt took 70 seconds.
|
|
|
Time to Determination of ETT Position
Overall and excluding the 13 abandoned attempts for which no assessment of tube position was required, the mean (SD; range) time taken to determine ETT position was 33 seconds (28; 1127). The mean (SD [range]) time to identify successful and unsuccessful attempts was not significantly different (32 [26] vs. 38 [37]; P = .55). The mean (SD; range) time taken for clinical assessment of ETT position (n = 33) was 39 seconds (30; 1127); for flow signals (n = 7) and ETCO2 (n = 7), it was 19 seconds (16; 853) and 17 seconds (20; 460), respectively. The time taken to assess tube position exceeded the time taken to intubate the infant on 15 (45%), 1 (14%), and 2 (29%) occasions for which clinical assessment, flow signals, and ETCO2, respectively, were used.
Pulse Oximetry During Intubation Attempts
Twenty-seven infants had pulse oximetry during 51 intubation attempts. The oximetry sensor was applied to the infant at a mean (SD) of 53(20) seconds of life, and data were displayed at a mean (SD) of 80 (27) seconds of life. The mean (SD; range) time at which intubation was attempted was 253 seconds (135; 86699).
Overall, infants deteriorated during 25 (49%) of these attempts. Compared with the value just before the intubation attempt, SpO2 alone fell by
10% in 9, HR alone fell by
10% in 4, and both fell by
10% in 12. The time at which infants deteriorated during intubation was variable, ranging from 2 to 55 seconds (mean: 20; SD: 13). Of the 12 attempts that were <20 seconds, no infant deteriorated during the attempt. Infants deteriorated during 4 of the 12 attempts that were between 20 and 29 seconds and 20 of the 27 attempts that were
30 seconds. Infants were monitored during 30 successful intubation attempts and deteriorated during 14; during the 21 failed attempts, 11 deteriorated.
As the reasons for intubation varied, so did the infants' condition before the attempt, eg, infants who were intubated for bradycardia despite mask ventilation had lower HR than infants who were randomly assigned in the COIN trial. Sixteen infants had HR <100 before intubation was attempted; 10 of these infants deteriorated during the attempt. Of the 35 infants who had HR
100, 15 deteriorated. The mean SpO2 of the infants at the time intubation was attempted was 70%. Of the 25 infants with SpO2 <70%, 17 deteriorated; of the 26 infants with SpO2
70%, 8 deteriorated.
| DISCUSSION |
|---|
|
|
|---|
This study shows that intubation is successful only
60% of the time. Even when practitioners with considerable experience attempt intubation, many infants are not intubated within the 20-second limit suggested by the NRP.2 In addition to fellows who are always present, consultant neonatologists frequently attend high-risk deliveries at our hospital, reflected by the relatively high proportion (35%) of attempts made by this group in our study. Our findings that consultants are more likely to intubate infants successfully and more quickly support the practice of having experienced senior staff present for back-up at high-risk deliveries.
An interval that rarely is considered in the time taken for intubation is the time taken for clinicians to decide whether the ETT is placed correctly. In our study, this frequently took longer than intubation itself when clinical assessment alone was used. Our study suggests that, as has already been suggested for ETCO2,13,14 flow signals may be useful in determining ETT position more quickly than clinical assessment alone. However, as also shown in this study, neither method is fool-proof, and both require additional evaluation.
In our study, infants frequently deteriorated during intubation attempts as determined by pulse oximetry. It seems that the more unwell the infant at the time of intubation, as indicated by the lower HR and SpO2, the more likely they were to deteriorate during the procedure. For most of these infants, deterioration was not readily apparent on observation, and it is unlikely that it would have been identified quickly by intermittent assessment of the HR, by either auscultation or palpation. Although infants deteriorated more frequently during longer intubation attempts, the timing of deterioration was highly variable. For example, of the 20 infants who deteriorated during attempts of >30 seconds' duration, 12 had already done so by 20 seconds. Thus, rather than impose a general time limit for intubation attempts, we advocate improved monitoring of infants in the DR (eg, the use of pulse oximetry) and limiting the duration of intubation attempts according to their individual response.