This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ariagno, R. L.
Right arrow Articles by Baldwin, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ariagno, R. L.
Right arrow Articles by Baldwin, R. B.
Related Collections
Right arrow Premature & Newborn
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

PEDIATRICS Vol. 111 No. 3 March 2003, pp. 622-625

Effect of Position on Sleep, Heart Rate Variability, and QT Interval in Preterm Infants at 1 and 3 Months’ Corrected Age

Ronald L. Ariagno, MD*, Majid Mirmiran, MD*,§, Marian M. Adams, MD*, Anna G. Saporito, MS*, Anne M. Dubin, MD{ddagger} and Roger B. Baldwin, MA*

* Departments of Pediatrics
{ddagger} Pediatric Cardiology, Stanford University School of Medicine, Stanford, California
§ Netherlands Institute for Brain Research, Amsterdam, the Netherlands

-->
    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Objective. Prone sleeping position has a strong link to sudden infant death syndrome (SIDS), and the "Back to Sleep" campaign has played an important role in reducing SIDS. We tested the hypothesis that the mechanism of the sleep position effect is based on changes in sleep, arousal, heart rate variability (HRV), and the QT interval of the electrocardiogram.

Study Design. We studied 16 premature infants longitudinally, at 1 and 3 months’ corrected age. Videosomnography recordings were made during the infants’ normal daytime naps. Each infant was recorded in both supine and prone positions. The recordings were analyzed in 30-second epochs, which were classified as awake, active sleep (AS), quiet sleep (QS), or indeterminate sleep. Electrocardiogram data were sampled with an accuracy of 1 millisecond. Time domain analysis of HRV was measured by standard deviation of all R-R intervals and by the square root of the mean of the sum of the squares of the differences between adjacent R-R intervals. Frequency domain analysis was done for low frequency (0.04–0.14 Hz) and high frequency (0.15–0.5 Hz) HRV. We measured QT, JT, and R-R intervals during AS and QS for each position.

Results. We found no significant differences between supine and prone position, either in total sleep time or in percentage of QS. Percentage of AS was significantly lower in the supine position, but only at 1 month corrected age. The incidence of short, spontaneous, sleep transitions was significantly higher in supine, also only at 1 month corrected age. Time domain analysis of HRV showed a significantly lower variability in prone, but only during QS. Frequency domain analysis of HRV showed no differences between the 2 sleeping positions. Both QT and JT intervals were significantly longer in prone during QS, but only at 1 month corrected age.

Conclusions. Despite the commonly held belief, prone position did not substantially increase total sleep at these ages. On the other hand, prone sleeping decreased the number of sleep transitions at 1 month corrected age, increased QT and JT intervals, and reduced HRV, thereby potentially increasing the vulnerability for SIDS. This study supports "Back to Sleep" as the position of choice not only for term but also for preterm infants after discharge home.

Key Words: sleep • QT interval • prone • supine • heart rate variability

Abbreviations: SIDS, sudden infant death syndrome • QTc, corrected QT interval • HRV, heart rate variability • PCA, postconceptual age • W, awake • AS, active sleep • QS, quiet sleep • IS, indeterminate sleep • ECG, electrocardiogram • SDNN, standard deviation of all R-R intervals • RMSSD, mean of the sum of the squares of differences between adjacent R-R • LF, low frequency • HF, high frequency • SD, standard deviation


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Sudden infant death syndrome (SIDS) has been independently associated with both prone sleeping position and prolonged QT interval.1,2 Since the "Back to Sleep" campaign, the frequency of prone sleeping position in the United States has decreased from >70% to only 24%.3 The rate of SIDS has concomitantly decreased by 38%. Despite this, a substantial number of infants continue to be placed in the prone sleeping position. The majority of caregivers, at home or in day care centers, who placed the infants in the prone sleeping position believe that the "infants sleep better that way."4

There is substantial scientific evidence that the prone sleeping position increases the risk of SIDS, but the mechanism by which positioning and/or sleep states increase this risk has not been elucidated. A prolonged, corrected QT interval (QTc) has been hypothesized as a marker of cardiac electrical instability, therefore increasing the likelihood of a lethal ventricular arrhythmia.2 Schwartz et al2 have shown significantly longer QTc in SIDS victims. They speculated that prolongation of the QTc interval may be attributable to developmental alterations in cardiac sympathetic innervation. An alternative possibility is that a prolonged QTc is a marker of a genetic abnormality, which predisposes the patient to lethal arrhythmias particularly when placed prone.5 Alternatively, we hypothesize a lower number of spontaneous arousals, lower heart rate variability (HRV), and a prolonged QTc during prone sleep may increase the likelihood for cardiorespiratory failure. In support of this hypothesis, a number of studies showed depressed arousal responses and HRV to external stimuli in prone versus supine in term infants.68

Preterm infants are at much higher risk of SIDS than term infants.911 The association between prone sleeping and SIDS seems to be even stronger among low birth weight infants.12 Earlier, we had studied preterm infants at discharge, around 36 weeks’ postconceptual age (PCA). We found fewer arousals and reduced HRV in prone position.13 In the current study, we extended the time period of the study to examine the effects of prone sleeping position at a later developmental period, ie, at 1 and 3 months’ corrected age. To better understand the mechanism(s) of SIDS, we have tested the hypothesis that sleep position may influence sleep transitions, HRV, and QTc in formerly premature infants at 1 and 3 months’ corrected age.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
Sixteen asymptomatic preterm infants (6 girls and 10 boys) with a mean gestational age of 34.4 ± 2.2 weeks (range: 28–36 weeks) and mean birth weight of 2326 ± 493 g (range: 1172–3000 g) were studied longitudinally at 1 and 3 months’ corrected age at home. These infants did not have any medical problems and were not on medications at the time of the study. Each infant was recorded at their usual nap time, between 11 AM and 4 PM. Sensors were placed on the infant before feeding and the recording was then started right after the completion of feeding. The initial sleeping position was randomized. After 1 to 1.5 hours of recording, the infant was gently, without awakening, placed in the complementary position.

The protocol was approved by the Human Subjects Institutional Review Board at Stanford University. Informed parental consent was obtained before the study.

Polysomnographic recordings were performed with an ambulatory digital recorder (Embla; Flaga hf. Medical Devices, Reykjavik, Iceland, 4.5 x 8.3 x 13.3 cm). The following variables were recorded simultaneously: 2 channels electroencephalogram (C4/A1 and C3/A2), an electrocardiogram (lead II); air flow (BreathSensor; Model 976; Nellcor Puritan Bennett Inc, Minneapolis, MN); thoracic respiratory effort (Crystal Trace Piezo Respiratory Effort Belt; Pro-Tech Services Inc, Woodinville, WA); and transcutaneous oxygen saturation and pulse rate (Pulse Oximeter Sensor, Models 8001J & 8008J; Nonin Medical Inc, Minneapolis, MN). All data were stored on hard disk and later analyzed using Somnologica software (Flaga hf. Medical Devices, Reykjavik, Iceland). Synchronized time-lapse video recordings (Panasonic, model AG6730, Osaka, Japan) were made simultaneously with the digital recordings. The camera framed the infant’s face and upper body for interpretation of sleep behavior (see Goto et al13 for further details).

Sleep State Analysis
Each 30-second epoch of the recording was analyzed and classified as Awake (W), Active Sleep (AS), Quiet Sleep (QS), or Indeterminate Sleep (IS) according to criteria in the literature.14 Percentages of each sleep state were calculated relative to the total sleep time in each position for each age. The number of transitions from one state to another was determined for each position. The number of transitions method was chosen rather than spontaneous arousals since, at this time, there is no consensus or universally accepted criteria for defining spontaneous arousal.

Electrocardiogram (ECG) Analysis
ECG data were sampled at an effective accuracy of 1 millisecond. Artifacts on ECG traces were identified by visual inspection and periods with artifact were excluded from additional analysis. Somnologica software for HRV analysis was used to examine the data.15 Time domain analyses included standard deviation of all R-R intervals (SDNN) and the square root of the mean of the sum of the squares of differences between adjacent R-R (RMSSD). Frequency domain analyses were done for low frequency (LF; 0.04–0.14 Hz) and high frequency (HF; 0.15–0.5 Hz) HRV. These measurements were based on standard criteria.16 All artifact-free episodes lasting at least 2 minutes during each sleep state, AS and QS, in each position were used for analysis.

An experienced pediatric cardiologist (A.M.D.) randomly selected 10 R-R intervals for each position and sleep state and manually measured QT, R-R, and JT intervals during AS and QS for each position.17 The JT interval, from the end of the QRS complex to the end of the T wave, was measured to account for any interventricular conduction delay.17 These measures, QT and JT, were corrected for heart rate using Bazett’s formula, yielding QTc and JTc. Average QTcs and JTcs for each position and each sleep state were then obtained. Any periods of apnea >=10 s, oxygen desaturation <90%, or bradycardia <80 beats per minute were also recorded.

Statistical Analysis
All values are expressed as mean ± 1 standard deviation (SD). Statistical analyses were done with paired t tests. Significance was accepted at P <= .05.


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
The sleep characteristics of both positions are summarized with means and SDs in Table 1. We found no significant differences in total sleeping time and %QS between the supine and prone positions (Table 1). The %AS was significantly lower in supine, but only at 1 month corrected age. The incidence of sleep transitions and %IS were significantly higher in supine, but only at 1 month corrected age.


View this table:
[in this window]
[in a new window]
 
TABLE 1. Comparison of Sleep Characteristics Between Prone and Supine Sleep Positions

 
Time domain analysis of the HRV showed significant differences in the sleeping position during QS, but not in AS (Table 2). The RMSSD was significantly greater in the supine position at both 1 and 3 months’ corrected age, whereas the SDNN was significantly higher in the supine position, but only at 1 month corrected age. Frequency domain analysis of HRV, on the other hand, showed no differences between the 2 sleeping positions either in LF or HF except for higher HF during QS in supine at 1 month corrected age (Table 3). QTc and JTc were significantly longer in prone but only at 1 month corrected age (Table 4). No apnea, desaturation, or bradycardia episodes were found in any infant in either sleeping position.


View this table:
[in this window]
[in a new window]
 
TABLE 2. Time Domain Analysis of HRV

 

View this table:
[in this window]
[in a new window]
 
TABLE 3. Frequency Domain Analysis of HRV

 

View this table:
[in this window]
[in a new window]
 
TABLE 4. QT and JT Intervals Compared With Sleep Position

 

    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 
At 1 month corrected age, we found a small but significant reduction in %AS in the supine sleeping position; however, this was accompanied by an increased %IS and no change in %QS or total sleep time. At 3 months’ corrected age, on the other hand, no significant differences were found between prone and supine sleeping positions. Although prone position may indeed increase duration of QS right after feeding in preterm infants before discharge, there is no significant difference in overall sleep pattern at later age.18,19 These results contradict the common belief that a preterm or term infant may sleep better/longer when in the prone sleeping position.4,20 Our earlier study of preterm infants before discharge also failed to show any significant effect of position on amount of sleep.18 The strength of our study is that each infant served as its own control. Differences between prone and supine in this study could not be attributed to the typical large individual sleep differences in infants. On the other hand, to record the infant in both positions on a single afternoon, we were not able to record each infant for longer than 1 to 1.5 hours in each position. A longer overnight home study was impractical, less acceptable to parents, and we wanted to avoid laboratory influences on sleep pattern of the infant.20 Although daytime naps may not be representative of nighttime sleep, we could not find evidence for substantial changes in amount of sleep based on position. We believe that although SIDS is associated with sleep, the amount of AS or QS per se may not be the determining factor in the occurrence of SIDS.

Prone position, by virtue of centrally increasing arousal threshold and upper airway resistance, may well serve as a potential independent risk factor in SIDS.21 The decreased number of sleep transitions at 1 month corrected age in our study supports this hypothesis. Because the tendency of infants to sleep during the day decreases by 3 months’ corrected age (because of the development of circadian rhythms22), this may have influenced the number of sleep transitions at this age. Investigators recording spontaneous and evoked arousals have shown the influence of sleep state and sleep position in term and preterm infants6,7,2328). Galland et al25 showed lower HRV in prone versus supine in term infants at 1 and 3 months of age. Franco et al27 showed significantly more intense stimuli were required to induce arousal during REM sleep in prone versus supine. Arousal threshold in response to air-jet stimulation was significantly higher in prone versus supine both in active and in quiet sleep.23 Skadberg and Markestad26 found significantly less short arousals in prone versus supine during REM sleep but not during QS.

Time domain analysis of HRV, particularly RMSSD, which is a measure of variability in successive intervals, showed significant reduction of HRV in prone sleeping position both at 1 and 3 months’ corrected age. Both RMSSD and SDNN values during QS in prone were consistently lower than supine (Table 3). No significant differences in frequency domain analysis of HRV were found. The reduction in HRV, particularly RMSSD, which is a measure of the degree of parasympathetic influences on heart rate over time, is interesting and is consistent with our earlier studies in preterm infants before discharge.13 Similar results have been reported by other investigators in term infants at 1 to 3 months’ corrected age and in preterm infants in the nursery.19,25 Reduction in HRV after cardiac arrest has been considered a potential risk factor for cardiac arrhythmia in adult patients. For the preterm infant, we speculate that a decrease in sleep transitions in combination with reduced autonomic function variability at a critical age could increase the risk for SIDS.29,30

Although the JTc and QTc intervals were within a normal clinical range, statistically significant increases were found during QS at 1 month corrected age. JTc and QTc were both shorter at 3 months’ corrected age compared with 1 month. Prolongation of the QTc interval has been associated with imbalances of sympathetic and parasympathetic tone; these imbalances may permit lethal ventricular arrhythmias to develop in those patients who are at risk of long QT syndrome.2 On the other hand, the QT may not adequately reflect the autonomic state in this patient population. QT prolongation may be evident only if the cellular substrate for prolonged QT syndrome is present. In the light of the provocative results reported by Schwartz,2 we may expect even further increase of QT interval during QS in prone sleeping position in patients with long QT syndrome. Although both sleeping position and QT intervals are risk factors for sudden infant death syndrome, they do not appear to be related. Additional study of the relationship between sleeping position and the autonomic nervous system is warranted.

Beneficial influences of prone sleeping position have been found in critically ill preterm infants in the neonatal intensive care unit.31 We have found no clinically significant apnea, oxygen desaturation, or bradycardia in asymptomatic preterm infants before discharge from the hospital13 or at 1 and 3 months’ corrected age at home. A recent study of 22 symptomatic preterm infants with gestational age ranging from 24 to 30 weeks, recorded at 28 to 36 weeks’ PCA in the neonatal intensive care unit failed to show any beneficial influence of prone position on apnea, bradycardia, or desaturation.32 Keene et al’s data as well as ours are in support of the statement of the Task Force of the American Academy of Pediatrics on SIDS1 for preterm infants. The American Society of Gastroenterology recently indicated that prone positioning as a therapy for reflux in infants is no longer generally recommended because of the concern for an increase risk for SIDS.33 There is simply no good reason to place a healthy infant in the prone sleeping position despite the myths of improved sleep, reduced choking, and increased cardiorespiratory stability.34


    ACKNOWLEDGMENTS
 
This study was supported by a Lucile Packard Children’s Hospital, Children’s Health Initiative grant.


    FOOTNOTES
 
Received for publication Feb 12, 2002; Accepted Jul 1, 2002.

Address correspondence to Ronald L. Ariagno, MD, Department of Pediatrics, Stanford University School of Medicine, 750 Welch Rd, Ste 315, Palo Alto, CA 94304. E-mail: rla{at}stanford.edu


    REFERENCES
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 REFERENCES
 

  1. American Academy of Pediatrics, Task Force on Infant Sleep Position and Sudden Infant Death Syndrome. Changing concepts of sudden infant death syndrome: implications for infant sleeping environment and sleep position. Pediatrics.2000; 105 :650 –656[Abstract/Free Full Text]
  2. Schwartz PJ, Stramba-Badiale M, Segantini A, et al. Prolongation of the QT interval and the sudden infant death syndrome. N Engl J Med.1998; 338 :1709 –1714[Abstract/Free Full Text]
  3. Willinger M, Hoffman HJ, Wu KT, et al. Factors associated with the transition to non-prone sleep position of infants in the United States. JAMA.1998; 280 :329 –335[Abstract/Free Full Text]
  4. Willinger M, Ko CW, Hoffman HJ, Kessler RC, Corwin MJ. Factors associated with caregivers’ choice of infant sleep position, 1994–1998: the National Infant Sleep Position Study. JAMA.2000; 283 :2135 –1242[Abstract/Free Full Text]
  5. Schwartz PJ, Priori SG, Dumaine R, et al. A molecular link between the sudden infant death syndrome and the long-QT syndrome. N Engl J Med.2000; 343 :262 –267[Free Full Text]
  6. Galland BC, Hayman RM, Taylor BJ, Bolton DP, Sayers RM, Williams SM. Factors affecting heart rate variability and heart rate responses to tilting in infants aged 1 and 3 months. Pediatr Res.2000; 48 :60 –68
  7. Franco P, Groswasser J, Sottiaux M, Broadfield E, Kahn A. Decreased cardiac responses to auditory stimulation during prone sleep. Pediatrics.1996; 97 :174 –178[Abstract/Free Full Text]
  8. Franco P, Pardou A, Hassid S, Lurquin P, Grosswasser J, Kahn A. Auditory arousal thresholds are higher when infants sleep in the prone position. J Pediatr.1998; 132 :240 –243[CrossRef][Web of Science][Medline]
  9. Grether JK, Schulman J. Sudden infant death syndrome and birth weight. J Pediatr.1989; 114 :561 –567[CrossRef][Web of Science][Medline]
  10. Malloy MH, Hoffman HJ. Prematurity, sudden infant death syndrome, and age of death. Pediatrics.1995; 96 :464 –471[Abstract/Free Full Text]
  11. Malloy MH, Freeman DH Jr. Birth weight- and gestational age-specific sudden infant death syndrome mortality: United States, 1991 versus 1995. Pediatrics.2000; 105; 1227 –1231[Abstract/Free Full Text]
  12. Oyen N, Markestad T, Skaerven R, et al. Combined effects of sleeping position and prenatal risk factors in sudden infant death syndrome: the Nordic Epidemiological SIDS Study. Pediatrics.1997; 100 :613 –621[Abstract/Free Full Text]
  13. Goto K, Mirmiran M, Adams MM, et al. More awakenings and heart rate variability during supine sleep in preterm infants. Pediatrics.1999; 103 :603 –609[Abstract/Free Full Text]
  14. Anders T, Emde R, Parmelee A. A Manual of Standardized Terminology, Technique and Criteria for Scoring States of Sleep and Wakefullness in Newborn Infants. Los Angles, CA: UCLA Brain Information Service BRI Publications Office, NINDS Neurological Information Network; 1971
  15. Bronzino J. The Biomedical Engineering Handbook. ISBN 0–8493-8346–3. Boca Raton, FL: CRC Press in cooperation with IEEE Press; 1995
  16. Task Force Of The European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation.1996; 93 :1043 –1065[Free Full Text]
  17. Dubin A, Kikkert M, Mirmiran M, Ariagno R. Cisapride associated with QTc prolongation in very low birth weight preterm infants. Pediatrics.2001; 107; 1313 –1316[Abstract/Free Full Text]
  18. Goto K, Mirmiran M, Adams MM, Longford RV, et al. More awakenings and heart rate variability during supine sleep in preterm infants. Pediatrics.1999; 103 :603 –609
  19. Sahni R, Schulze KF, Kashyap S, OhiraKist K, Myers MM, Fifer WP. Body position; sleep states; and cardiorespiratory activity in developing low birth weight infants. Early Hum Dev.1999; 54 :197 –206[CrossRef][Web of Science][Medline]
  20. Kahn A, Groswasser J, Sottiaux M, Rebuffat E, Franco P, Dramaix M. Prone or supine body position and sleep characteristics in infants. Pediatrics.1993; 91 :1112 –1115[Abstract/Free Full Text]
  21. Davidson Ward S, Keens T. Maturation of the arousal response. In: Loughlin GM, Carroll J, Marcu C, eds. Sleep and Breathing in Children: A Developmental Approach. New York, NY: Marcel Dekker, Inc; 2000:79–97
  22. Mirmiran M, Ariagno RL. Influence of light in the NICU on the development of circadian rhythms in preterm infants. Semin Perinatol.2000; 24 :247 –257[CrossRef][Web of Science][Medline]
  23. Horne RS, Ferens D, Watts AM, et al. The prone sleeping position impairs arousability in term infants. J Pediatr.2001; 138 :811 –816[CrossRef][Web of Science][Medline]
  24. Horne RS, Sly DJ, Cranage SM, Chau B, Adamson TM. Effects of prematurity on arousal from sleep in the newborn infant. Pediatr Res.2000; 47 :468 –474[Web of Science][Medline]
  25. Galland BC, Reeves G, Taylor BJ, Bolton DP. Sleep position, autonomic function, and arousal. Arch Dis Child Fetal Neonatal Ed.1998; 78 :F189 –F194[Abstract/Free Full Text]
  26. Skadberg BT, Markestad T. Behaviour and physiological responses during prone and supine sleep in early infancy. Arch Dis Child.1997; 76 :320 –324[Abstract/Free Full Text]
  27. Franco P, Pardou A, Hassid S, Lurquin P, Groswasser J, Kahn A. Auditory arousal thresholds are higher when infants sleep in the prone position. J Pediatr.1998; 132 :240 –243
  28. Read PA, Horne RS, Cranage SM, Walker AM, Walker DW, Adamson TM. Dynamic changes in arousal threshold during sleep in the human infant. Pediatr Res.1998; 43 :697 –703[Web of Science][Medline]
  29. Filiano JJ, Kinney HC. A perspective on neuropathologic findings in victims of the sudden infant death syndrome: the triple-risk model. Biol Neonate.1994; 65 :194 –197[CrossRef][Web of Science][Medline]
  30. Ariagno R, Mirmiran M. Arousal and brain homeostatic control. In: Byard R, Krous H, eds. Sudden Infant Death Syndrome: Problems, Progress, & Possibilities. London, United Kingdom: Arnold; 2001:96–117
  31. Martin RJ, Okken A. Arterial oxygen tension during active and quiet sleep in the normal neonate. Pediatrics.1979; 94 :271 –274
  32. Keene DJ, Wimmer JE Jr, Mathew OP. Does supine positioning increase apnea, bradycardia, and desaturation in preterm infants? J Perinatol.2000; 20 :17 –20[CrossRef][Medline]
  33. Rudolph CD, Mazur LJ, Liptak GS, et al. Evaluation and treatment of gastroesophageal reflux in infants and children: an evidence-based review for a clinical guideline—pediatric GE reflux clinical practice guidelines. J Pediatr Gastroenterol Nutr.2001; 32(suppl 2) :S1 –S31
  34. Jeffery HE, Megevand A, Page H. Why the prone position is a risk factor for sudden infant death syndrome. Pediatrics.1999; 104 :263 –269[Abstract/Free Full Text]

PEDIATRICS (ISSN 1098-4275). ©2003 by the American Academy of Pediatrics

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
BloodHome page
M. Bosticardo, F. Marangoni, A. Aiuti, A. Villa, and M. Grazia Roncarolo
Recent advances in understanding the pathophysiology of Wiskott-Aldrich syndrome
Blood, June 18, 2009; 113(25): 6288 - 6295.
[Abstract] [Full Text] [PDF]


Home page
J. Immunol.Home page
S. Trifari, G. Sitia, A. Aiuti, S. Scaramuzza, F. Marangoni, L. G. Guidotti, S. Martino, P. Saracco, L. D. Notarangelo, M.-G. Roncarolo, et al.
Defective Th1 Cytokine Gene Transcription in CD4+ and CD8+ T Cells from Wiskott-Aldrich Syndrome Patients
J. Immunol., November 15, 2006; 177(10): 7451 - 7461.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
R Sahni, K F Schulze, S Kashyap, K Ohira-Kist, W P Fifer, and M M Myers
Sleeping position and electrocortical activity in low birthweight infants
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2005; 90(4): F311 - f315.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
J R Skinner
Is there a relation between SIDS and long QT syndrome?
Arch. Dis. Child., May 1, 2005; 90(5): 445 - 449.
[Full Text] [PDF]


Home page
NeoReviewsHome page
R. L. Ariagno and M. Mirmiran
Back to Sleep for Preterm Infants to Reduce the Risk of SIDS
NeoReviews, November 1, 2003; 4(11): e305 - 307.
[Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Web of Science (9)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ariagno, R. L.
Right arrow Articles by Baldwin, R. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ariagno, R. L.
Right arrow Articles by Baldwin, R. B.
Related Collections
Right arrow Premature & Newborn
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?