PEDIATRICS Vol. 97 No. 3 March 1996, pp. 413-416
This Article
Right arrow Full Text (PDF)
Right arrow P3Rs: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when P3Rs are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation

Aluminum Toxicity in Infants and Children

COMMITTEE ON NUTRITION

Dialysis encephalopathy and fracturing osteomalacia, which occur in hemodialysis units that use dialysis fluid contaminated with aluminum, have largely disappeared. This has been accomplished by establishing standards for safe concentrations of aluminum in dialysates. Infants, children, and adults with chronic renal failure who are not receiving dialysis have been shown to be at risk for aluminum intoxication from the oral administration of aluminum-containing phosphate binders. This complication should be avoided with the use of phosphate binders that do not contain aluminum and the use of other measures to control hyperphosphatemia.

A number of substances commonly administered intravenously, including calcium and phosphorus salts and albumin, have high levels of aluminum. Premature infants receiving intravenous fluid therapy may accumulate aluminum and show evidence of aluminum toxicity. Efforts are being made to reduce the levels of aluminum in products added to intravenous solutions; these efforts must continue.

Some infant formulas may contain relatively high concentrations of aluminum. The reported concentrations of aluminum in soy formulas and premature infant formulas are higher than those in other infant formulas. The potential impact of these formulas on the aluminum intake of premature infants and infants with impaired renal function should be recognized, although it is not clear that toxic effects result from the use of the formulas in these situations.


Statement of reaffirmation:

AAP Publications Retired and Reaffirmed

Pediatrics 114: 1126-1126. [Full Text]



This article has been cited by other articles:


Home page
JPEN J Parenter Enteral NutrHome page
R. L. Poole, S. R. Hintz, N. I. Mackenzie, and J. A. Kerner Jr
Aluminum Exposure From Pediatric Parenteral Nutrition: Meeting the New FDA Regulation
JPEN J Parenter Enteral Nutr, May 1, 2008; 32(3): 242 - 246.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
J. Bhatia, F. Greer, and and the Committee on Nutrition
Use of Soy Protein-Based Formulas in Infant Feeding
Pediatrics, May 1, 2008; 121(5): 1062 - 1068.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
Committee on Nutrition
Soy Protein-based Formulas: Recommendations for Use in Infant Feeding
Pediatrics, January 1, 1998; 101(1): 148 - 153.
[Abstract] [Full Text] [PDF]