Pulse oximetry has gained widespread use in neonatal oxygen monitoring. However, because specific morbidity in neonates has been related to abnormal levels of oxygen partial pressure (Pao2), it is essential to demonstrate that pulse oxygen saturation values (Spo2) are highly accurate and reflect with precision the simultaneous Pao2. In this report, data is presented that describe the accuracy of the Ohmeda Biox 3700 pulse oximeter. Spo2 was highly correlated with arterial blood oxygen saturation (r = .99) measured on arterial (catheter) blood using a two-wavelength Radiometer OSM2 Hemoximeter. When compared with Pao2, Spo2 values of 92% ± 3% (mean ± range) excluded all of the measured Pao2 values less than 45 mm Hg and greater than 100 mm Hg. Spo2-tcPo2 (transcutaneous Po2) and Spo2-Pao2 (catheter or percutaneous arterial Po2) correlations showed that bronchopulmonary dysplasia, percutaneous arterial sampling, and nipple feeding skewed the tcPo2 but not the Pao2 correlations with Spo2, indicating that Spo2 is not sensitive to peripheral factors that affect tcPo2. Spo2-Pao2 correlation was not affected by gestational age. A high degree of accuracy of Spo2 values and Spo2 prediction of normal appearing Pao2 values are defined by these results.
Key Words: neonate oxygen pulse oximetry
Submitted on October 9, 1987
Accepted on June 20, 1988
This article has been cited by other articles:
![]() |
P. A. Kyriacou, D. P. Jones, R. M. Langford, and A. J. Petros A Pilot Study of Neonatal and Pediatric Esophageal Pulse Oximetry Anesth. Analg., September 1, 2008; 107(3): 905 - 908. [Abstract] [Full Text] [PDF] |
||||
![]() |
D Quine and B J Stenson Does the monitoring method influence stability of oxygenation in preterm infants? A randomised crossover study of saturation versus transcutaneous monitoring Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2008; 93(5): F347 - F350. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Claure Automated Regulation of Inspired Oxygen in Preterm Infants: Oxygenation Stability and Clinician Workload Anesth. Analg., December 1, 2007; 105(6S_Suppl): S37 - S41. [Abstract] [Full Text] [PDF] |
||||
![]() |
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al. Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86. [Abstract] [Full Text] [PDF] |
||||
![]() |
S.-Y. P. K. Shiao and C.-N. Ou Validation of Oxygen Saturation Monitoring in Neonates Am. J. Crit. Care., March 1, 2007; 16(2): 168 - 178. [Abstract] [Full Text] [PDF] |
||||
![]() |
J A Dawson, P G Davis, C P F O'Donnell, C O F Kamlin, and C J Morley Pulse oximetry for monitoring infants in the delivery room: a review Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2007; 92(1): F4 - F7. [Full Text] [PDF] |
||||
![]() |
W. W. Hay Jr History of Pulse Oximetry in Neonatal Medicine NeoReviews, December 1, 2005; 6(12): e533 - e538. [Full Text] [PDF] |
||||
![]() |
R Sahni, A Gupta, K Ohira-Kist, and T S Rosen Motion resistant pulse oximetry in neonates Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2003; 88(6): F505 - 508. [Abstract] [Full Text] [PDF] |
||||
![]() |
Statement on the Care of the Child with Chronic Lung Disease of Infancy and Childhood Am. J. Respir. Crit. Care Med., August 1, 2003; 168(3): 356 - 396. [Full Text] [PDF] |
||||
![]() |
S Kotecha and J Allen Oxygen therapy for infants with chronic lung disease Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2002; 87(1): F11 - 14. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Grap Pulse Oximetry Crit. Care Nurse, June 1, 2002; 22(3): 69 - 74. [Full Text] [PDF] |
||||
![]() |
J. P. Shenai, B. G. Mellen, and F. Chytil Vitamin A Status and Postnatal Dexamethasone Treatment in Bronchopulmonary Dysplasia Pediatrics, September 1, 2000; 106(3): 547 - 553. [Abstract] [Full Text] |
||||
![]() |
J. Medves Individualised limits for SpO2 were no better than fixed limits for detecting hypoxia or hyperoxia in sick infants Evid. Based Nurs., July 1, 2000; 3(3): 85 - 85. [Full Text] |
||||
![]() |
R Gupta, C W Yoxall, N Subhedar, and N J Shaw Individualised pulse oximetry limits in neonatal intensive care Arch. Dis. Child. Fetal Neonatal Ed., November 1, 1999; 81(3): 194F - 196. [Abstract] [Full Text] |
||||
![]() |
M J Gamponia, H Babaali, F Yugar, and R H Gilman Reference values for pulse oximetry at high altitude Arch. Dis. Child., May 1, 1998; 78(5): 461 - 465. [Abstract] [Full Text] |
||||
![]() |
R. T. Brouillette and D. H. Waxman Evaluation of the newborn's blood gas status Clin. Chem., January 1, 1997; 43(1): 215 - 221. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Niermeyer, P. Yang, Shanmina, Drolkar, J. Zhuang, and L. G. Moore Arterial Oxygen Saturation in Tibetan and Han Infants Born in Lhasa, Tibet N. Engl. J. Med., November 9, 1995; 333(19): 1248 - 1252. [Abstract] [Full Text] [PDF] |
||||
![]() |
C D Hanning and J M Alexander-Williams Fortnightly Review: Pulse oximetry: a practical review BMJ, August 5, 1995; 311(7001): 367 - 370. [Abstract] [Full Text] |
||||