PEDIATRICS Vol. 83 No. 5 May 1989, pp. 717-722
This Article
Right arrow Full Text (PDF)
Right arrow P3Rs: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when P3Rs are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hay, W. W.
Right arrow Articles by Eyzaguirre, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hay, W. W., Jr
Right arrow Articles by Eyzaguirre, M.

Neonatal Pulse Oximetry: Accuracy and Reliability

William W. Hay Jr MD1, Julia M. Brockway BA1, and Mario Eyzaguirre MD1

1 The Neonatal Clinical Research Center, Department of Pediatrics, University of Colorado School of Medicine, Denver

Pulse oximetry has gained widespread use in neonatal oxygen monitoring. However, because specific morbidity in neonates has been related to abnormal levels of oxygen partial pressure (Pao2), it is essential to demonstrate that pulse oxygen saturation values (Spo2) are highly accurate and reflect with precision the simultaneous Pao2. In this report, data is presented that describe the accuracy of the Ohmeda Biox 3700 pulse oximeter. Spo2 was highly correlated with arterial blood oxygen saturation (r = .99) measured on arterial (catheter) blood using a two-wavelength Radiometer OSM2 Hemoximeter. When compared with Pao2, Spo2 values of 92% ± 3% (mean ± range) excluded all of the measured Pao2 values less than 45 mm Hg and greater than 100 mm Hg. Spo2-tcPo2 (transcutaneous Po2) and Spo2-Pao2 (catheter or percutaneous arterial Po2) correlations showed that bronchopulmonary dysplasia, percutaneous arterial sampling, and nipple feeding skewed the tcPo2 but not the Pao2 correlations with Spo2, indicating that Spo2 is not sensitive to peripheral factors that affect tcPo2. Spo2-Pao2 correlation was not affected by gestational age. A high degree of accuracy of Spo2 values and Spo2 prediction of normal appearing Pao2 values are defined by these results.

Key Words: neonate • oxygen • pulse oximetry

Submitted on October 9, 1987
Accepted on June 20, 1988




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
P. A. Kyriacou, D. P. Jones, R. M. Langford, and A. J. Petros
A Pilot Study of Neonatal and Pediatric Esophageal Pulse Oximetry
Anesth. Analg., September 1, 2008; 107(3): 905 - 908.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
D Quine and B J Stenson
Does the monitoring method influence stability of oxygenation in preterm infants? A randomised crossover study of saturation versus transcutaneous monitoring
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2008; 93(5): F347 - F350.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
N. Claure
Automated Regulation of Inspired Oxygen in Preterm Infants: Oxygenation Stability and Clinician Workload
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S37 - S41.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al.
Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline
Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
S.-Y. P. K. Shiao and C.-N. Ou
Validation of Oxygen Saturation Monitoring in Neonates
Am. J. Crit. Care., March 1, 2007; 16(2): 168 - 178.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
J A Dawson, P G Davis, C P F O'Donnell, C O F Kamlin, and C J Morley
Pulse oximetry for monitoring infants in the delivery room: a review
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2007; 92(1): F4 - F7.
[Full Text] [PDF]


Home page
NeoReviewsHome page
W. W. Hay Jr
History of Pulse Oximetry in Neonatal Medicine
NeoReviews, December 1, 2005; 6(12): e533 - e538.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
R Sahni, A Gupta, K Ohira-Kist, and T S Rosen
Motion resistant pulse oximetry in neonates
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2003; 88(6): F505 - 508.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
Statement on the Care of the Child with Chronic Lung Disease of Infancy and Childhood
Am. J. Respir. Crit. Care Med., August 1, 2003; 168(3): 356 - 396.
[Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
S Kotecha and J Allen
Oxygen therapy for infants with chronic lung disease
Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2002; 87(1): F11 - 14.
[Abstract] [Full Text] [PDF]


Home page
Crit Care NurseHome page
M. J. Grap
Pulse Oximetry
Crit. Care Nurse, June 1, 2002; 22(3): 69 - 74.
[Full Text] [PDF]


Home page
PediatricsHome page
J. P. Shenai, B. G. Mellen, and F. Chytil
Vitamin A Status and Postnatal Dexamethasone Treatment in Bronchopulmonary Dysplasia
Pediatrics, September 1, 2000; 106(3): 547 - 553.
[Abstract] [Full Text]


Home page
Evid. Based Nurs.Home page
J. Medves
Individualised limits for SpO2 were no better than fixed limits for detecting hypoxia or hyperoxia in sick infants
Evid. Based Nurs., July 1, 2000; 3(3): 85 - 85.
[Full Text]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
R Gupta, C W Yoxall, N Subhedar, and N J Shaw
Individualised pulse oximetry limits in neonatal intensive care
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 1999; 81(3): 194F - 196.
[Abstract] [Full Text]


Home page
Arch. Dis. Child.Home page
M J Gamponia, H Babaali, F Yugar, and R H Gilman
Reference values for pulse oximetry at high altitude
Arch. Dis. Child., May 1, 1998; 78(5): 461 - 465.
[Abstract] [Full Text]


Home page
Clin. Chem.Home page
R. T. Brouillette and D. H. Waxman
Evaluation of the newborn's blood gas status
Clin. Chem., January 1, 1997; 43(1): 215 - 221.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
S. Niermeyer, P. Yang, Shanmina, Drolkar, J. Zhuang, and L. G. Moore
Arterial Oxygen Saturation in Tibetan and Han Infants Born in Lhasa, Tibet
N. Engl. J. Med., November 9, 1995; 333(19): 1248 - 1252.
[Abstract] [Full Text] [PDF]


Home page
BMJHome page
C D Hanning and J M Alexander-Williams
Fortnightly Review: Pulse oximetry: a practical review
BMJ, August 5, 1995; 311(7001): 367 - 370.
[Abstract] [Full Text]