PEDIATRICS Vol. 83 No. 2 February 1989, pp. 240-243
This Article
Right arrow Full Text (PDF)
Right arrow P3Rs: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when P3Rs are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Park, M. K.
Right arrow Articles by Lee, D.-H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Park, M. K.
Right arrow Articles by Lee, D.-H.

Normative Arm and Calf Blood Pressure Values in the Newborn

Myung K. Park MD1 and Da-Hae Lee MD1

1 The Department of Pediatrics, University of Texas Health Science Center, San Antonio

Indirect BP measurement was obtained in the right upper arm in 219 healthy newborn infants with the Dinamap monitor and was compared with values obtained from the calf to establish normative BP values and to help establish a diagnosis of hypertension and coarctation of the aorta in the newborn. There were 174 Mexican-Americans (79.5%), 33 whites (15.0%), and 12 blacks (5.5%). The width of the BP cuff was selected to be 0.4 to 0.5 times the circumference of the extremities. Three supine position readings of BPs and heart rate were obtained from each site and were averaged for statistical analyses. Mean arm BP values (±SD) of the neonate less than 36 hours of age were 62.6±6.9/38.9± 5.7 mm Hg (48.0±6.2 mm Hg). Neonates older than 36 hours had slightly but significantly (P<.05) greater values (4 to 6 mm Hg) than did infants younger than 36 hours of age. Active neonates had values 6 to 10 mm Hg greater than quiet neonates (P<.05). BP values in the calf obtained with the same-sized cuff were almost identical with those obtained from the arm. Differences in consecutively obtained arm and calf BPs (arm values minus calf values) were 1.1±7.7 mm Hg systolic, -0.01 ± 6.2 mm Hg diastolic, and 0.9 ±6.9 mm Hg mean pressures. Mean heart rate (±SD) of neonates less than 36 hours of age was 129.4± 13.2 beats per minute and that of neonates older than 36 hours of age was 139.4± 14.1 beats per minute. These results show the following: (1) arm BPs and calf BPs using the same-sized cuff are almost identical with mean values of approximately 65/ 41 mm Hg (50 mm Hg) in neonates one to three days of age, (2) arm BP of 75/49 mm Hg (59 mm Hg) or greater is in the hypertensive range, and (3) calf BPs that are less than arm BPs by mean + 1 SD (6 to 9 mm Hg) necessitate a thorough investigation for coarctation of the aorta.

Key Words: blood pressure • oscillometric method • newborn • hypertension • coarctation of aorta

Submitted on December 7, 1987
Accepted on January 28, 1988