PEDIATRICS Vol. 82 No. 5 November 1988, pp. 713-720
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muttitt, S. C.
Right arrow Articles by Rossmann, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muttitt, S. C.
Right arrow Articles by Rossmann, J.

Neonatal Apnea: Diagnosis by Nurse Versus Computer

Sarah C. Muttitt MD, FRCPC1, Neil N. Finer MD, FRCPC1, Anne J. Tierney MB, BCh, FRCPC1, and James Rossmann 1

1 From the Department of Newborn Medicine, Royal Alexandra Hospital, and Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada

In an effort to characterize significant neonatal apnea and evaluate the nursing diagnosis of apnea, apnea type and frequency were determined in 27 infants by continuous computer recording of heart rate, respiratory impedance, end-tidal CO2, and either or both transcutaneous oxygen and pulse oximetry. Of the 1,266 recorded apneas, 46% were central, 44% were mixed, and 10% were obstructive. Mixed apnea was associated with a longer mean duration and greater mean decrease in heart rate than central apnea. Apnea duration was positively correlated with both a decrease in heart rate and oxygen saturation (P < .001), and a lower baseline saturation was associated with a greater decrease in oxygen saturation during apnea (P = .002). Theophylline therapy had no effect on apnea duration or oxygen desaturation but resulted in a decrease in the mean heart rate decrease associated with apnea. Overall, nurses diagnosed 54% of all apneic episodes and were significantly poorer at detecting mixed and obstructive events. Nursing detection of apnea improved with increasing apnea duration and was always associated with a greater decrease in heart rate. Nurses diagnosed significantly fewer mixed apnea following theophylline therapy. Improved monitoring techniques, particularly for mixed and obstructive apnea, are essential to increase apnea detection in the nursery.

Key Words: apnea • computer • nurse • theophylline • newborn

Submitted on August 21, 1987
Accepted on November 18, 1987




This article has been cited by other articles:


Home page
NEJMHome page
B. Schmidt, R. S. Roberts, P. Davis, L. W. Doyle, K. J. Barrington, A. Ohlsson, A. Solimano, W. Tin, and the Caffeine for Apnea of Prematurity Trial Group
Long-Term Effects of Caffeine Therapy for Apnea of Prematurity
N. Engl. J. Med., November 8, 2007; 357(19): 1893 - 1902.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
P Steer, V Flenady, A Shearman, B Charles, P H Gray, D Henderson-Smart, G Bury, S Fraser, J Hegarty, Y Rogers, et al.
High dose caffeine citrate for extubation of preterm infants: a randomised controlled trial
Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2004; 89(6): F499 - F503.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
K. J. Barrington, D. Bull, and N. N. Finer
Randomized Trial of Nasal Synchronized Intermittent Mandatory Ventilation Compared With Continuous Positive Airway Pressure After Extubation of Very Low Birth Weight Infants
Pediatrics, April 1, 2001; 107(4): 638 - 641.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
R. A. Darnall, J. Kattwinkel, C. Nattie, and M. Robinson
Margin of Safety for Discharge After Apnea in Preterm Infants
Pediatrics, November 1, 1997; 100(5): 795 - 801.
[Abstract] [Full Text] [PDF]