PEDIATRICS Vol. 78 No. 4 October 1986, pp. 636-639
This Article
Right arrow Full Text (PDF)
Right arrow P3Rs: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when P3Rs are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gilhooly, J.
Right arrow Articles by Reynolds, J. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gilhooly, J.
Right arrow Articles by Reynolds, J. W.

Central Venous Silicone Elastomer Catheter Placement by Basilic Vein Cutdown in Neonates

Joseph Gilhooly MD1, Jeffrey Lindenberg MD1, and John W. Reynolds MD1

1 From the Department of Pediatrics, Oregon Health Sciences University, Portland

There is a need for central venous access in small premature infants and other neonates when enteral feeding is not tolerated or is contraindicated. We placed 83 small (0.635-mm od) silicone elastomer catheters by basilic vein cutdown through a subcutaneous tunnel in 79 patients during a 12-month period. Thirty-five patients (44%) weighed <1,000 g. Each patient on whom the procedure was attempted had successful placement of a catheter, and they remained in place a mean of 20 days (range three to 82). Patients had a mean weight gain of 15 g per day of catheter use. Sixty-two catheters (75%) were removed electively, 13 (16%) secondary to complications, six (7%) because of patient deaths (none catheter related), and two (2%) were accidentally dislodged. Two episodes of catheter-related sepsis (0.12 episodes per 100 days of catheter use) caused by Candida albicans and Staphylococcus epidermidis were encountered. Other complications included one subclavian vein thrombosis, eight catheter occlusions, and two local arm inflammations. This technique proved to be a safe, easy, and inexpensive method to administer parenteral nutrition to neonates, especially those weighing <1,000 g.

Key Words: central venous catheter • silicone elastomer catheter • hyperalimentation • neonate

Submitted on November 8, 1985
Accepted on February 14, 1986