PEDIATRICS Vol. 72 No. 6 December 1983, pp. 864-871
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Johnson, G. L.
Right arrow Articles by Ellison, R. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Johnson, G. L.
Right arrow Articles by Ellison, R. C.

Echocardiographic Characteristics of Premature Infants with Patent Ductus Arteriosus

Gregory L. Johnson MD, Gerard L. Breart MD, Michael H. Gewitz MD, Joel I. Brenner MD, Peter Lang MD, Kenneth J. Dooley MD, and R. Curtis Ellison MD

As part of a multicenter collaborative study, M-mode echocardiograms were obtained shortly after birth on 3,559 premature infants with birth weight le1,750 g. Of these infants, 1,496 did not develop a cardiac murmur or other signs of a "hemodynamically significant" patent ductus arteriosus (PDA). Echocardiographic parameters from this "normal" group were compared with results obtained from 415 infants in whom PDA was diagnosed on the basis of clinical findings alone, irrespective of the echocardiogram (PDA group). The best discrimination between the two groups, when considering a single parameter, was provided by a left atrial to aortic root ratio (LA/AO) of 1.40, a left ventricular to aortic root ratio (LV/AO) of 2.10, or a left ventricular systolic time interval ratio (LPEP/LVET) of 0.27. Multivariate analysis demonstrated that better separation between the two groups occurred when the left atrial to aortic root ratio and the left ventricular systolic time interval ratio were considered jointly. Because of a large degree of overlap of all echocardiographic variables between the normal group and the group with PDA, the echocardiogram alone was not a good indicator of PDA. However, when used in conjunction with a priori estimates of the probability of PDA (based, for example, on birth weight and degree of respiratory disease), use of echocardiographic data was found to improve the detection of hemodynamically significant patent ductus arteriosus in premature infants.

Key Words: patent ductus arteriosus • premature infants • echocardiography

Submitted on October 26, 1982
Accepted on March 1, 1983




This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
M El Hajjar, G Vaksmann, T Rakza, G Kongolo, and L Storme
Severity of the ductal shunt: a comparison of different markers
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2005; 90(5): F419 - F422.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
E. Heyman, I. Morag, D. Batash, R. Keidar, S. Baram, and M. Berkovitch
Closure of Patent Ductus Arteriosus With Oral Ibuprofen Suspension in Premature Newborns: A Pilot Study
Pediatrics, November 1, 2003; 112(5): e354 - 354.
[Abstract] [Full Text] [PDF]


Home page
CLIN PEDIATRHome page
R. C. McKone and K. M. Weesner
Determination of the Time of Closure of the Ductus Arteriosus in Severely III Premature Infants
Clinical Pediatrics, March 1, 1988; 27(3): 135 - 139.
[Abstract] [PDF]