PEDIATRICS Vol. 70 No. 6 December 1982, pp. 852-857
This Article
Right arrow Full Text (PDF)
Right arrow P3Rs: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when P3Rs are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kahn, A.
Right arrow Articles by Smets, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kahn, A.
Right arrow Articles by Smets, P.

Effects of Obstructive Sleep Apneas on Transcutaneous Oxygen Pressure in Control Infants, Siblings of Sudden Infant Death Syndrome Victims, and Near Miss Infants: Comparison with the Effects of Central Sleep Apneas

Andre Kahn MD1, Denise Blum MD1, P. Waterschoot MD1, E. Engelman MD1, and P. Smets MD1

1 The Department of Pediatrics, University Hospital Saint Pierre, and Laboratory for Medical Statistics, Free University of Brussels, Brussels

In order to investigate the effects of obstructive sleep apneas upon transcutaneous Po2 75 polysomnograms, recorded during night sessions in 25 control infants, 25 siblings, and 25 near miss for sudden infant death syndrome (SIDS) infants were studied. These observations were compared with the decreases in transcutaneous Po2 measured during central sleep apneas in the same infants. During a total of 707.6 hours of sleep, 33 obstructive apneas and 1,650 central apneas were recorded. Obstructive apneas were seen in three control infants (three episodes), one sibling (five episodes), and six near miss for SIDS infants (25 episodes). The obstructive apneas tended to be short (less than 10 seconds). Comparatively, the central apneas were equally distributed in the three groups of infants, and only the near miss children presented apneas that lasted as long as 19 seconds. The decrease in transcutaneous Po2 was proportional to the duration of both types of apnea, but for a given duration the decrease in transcutaneous Po2 was significantly greater for the obstructive apneas than for the central apneas (with a mean difference of 7.59 ± 0.53% Po2. It is concluded that the hypoxic effects of the obstructive apneas might have important clinical implications in infants, such as the near miss for SIDS.

Key Words: obstructive apneas • sudden infant death syndrome • transcutaneous oxygen pressure

Submitted on December 18, 1981
Accepted on June 23, 1982




This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
K. A. Waters and K. D. Tinworth
Habituation of Arousal Responses after Intermittent Hypercapnic Hypoxia in Piglets
Am. J. Respir. Crit. Care Med., June 1, 2005; 171(11): 1305 - 1311.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
T. Ishikawa, S. Isono, J. Aiba, A. Tanaka, and T. Nishino
Prone Position Increases Collapsibility of the Passive Pharynx in Infants and Small Children
Am. J. Respir. Crit. Care Med., September 1, 2002; 166(5): 760 - 764.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
R. Ramanathan, M. J. Corwin, C. E. Hunt, G. Lister, L. R. Tinsley, T. Baird, J. M. Silvestri, D. H. Crowell, D. Hufford, R. J. Martin, et al.
Cardiorespiratory Events Recorded on Home Monitors: Comparison of Healthy Infants With Those at Increased Risk for SIDS
JAMA, May 2, 2001; 285(17): 2199 - 2207.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
F. McNamara and C. E. Sullivan
Obstructive Sleep Apnea in Infants and Its Management With Nasal Continuous Positive Airway Pressure
Chest, July 1, 1999; 116(1): 10 - 16.
[Abstract] [Full Text] [PDF]