PEDIATRICS Vol. 65 No. 3 March 1980, pp. 515-522
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pollitzer, M. J.
Right arrow Articles by Delpy, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pollitzer, M. J.
Right arrow Articles by Delpy, D.

Effect of Electrode Temperature and in Vivo Calibration on Accuracy of Transcutaneous Estimation of Arterial Oxygen Tension in Infants

Melanie J. Pollitzer MB1, Michelle D. Whitehead BSc1, E. Osmund R. Reynolds FRCP1, and David Delpy BTech1

1 Departments of Paediatrics and Medical Physics and Bioengineering, University College Hospital and Medical School, London

Previous studies showed that a skin oxygen electrode with a macrocathode, when heated to 43 C, underestimated arterial oxygen tension (Pao2). At 44 C the skin was damaged. The purpose of the present study was to assess the accuracy of the macrocathode electrode when set at 43.5 C. Transcutaneous oxygen tension (tcPo2) recorded by the macrocathode electrode at 43.5 C was compared with Pao2 measured continuously with an intravascular oxygen electrode, and with tcPo2 recorded by a microcathode electrode which has been shown earlier to work well at a temperature of 44 C. Both the skin electrodes were calibrated in vitro and in vivo. Particular attention was given to the details of calibration. Twelve newborn infants with respiratory illnesses were studied, each for six hours. Transcutaneous Po2 recorded by both skin electrodes was found to estimate Pao2 resonably accurately for the entire six-hour duration of the study, with the exception of a large and unexplained overestimation of Pao2 by the macrocathode electrode in one infant. This overestimation was corrected by in vivo calibration. Serious skin lesions were not seen after the skin electrodes were removed. We conclude that (1) The temperature setting of skin electrodes is crucial to their satisfactory performance. (2) For use on newborn infants, 43.5 C is the optimal temperature for the macrocathode electrode. (3) The optimal temperature for the microcathode electrode was confirmed as 44 C. (4) At these temperatures, both electrodes could be left on the same site on the skin for six hours. (5) Periodic in vivo calibration of skin electrodes is advisable.

Submitted on February 2, 1979
Accepted on June 6, 1979