1 Children's Medical Center, Okayama National Hospital, Okayama, Japan
A new noninvasive bilirubinometer (Tc BM), which measures transcutaneous bilirubin level of the newborn, was developed as a joint effort by the present authors and the Minolta Camera Company, Ltd. A series of linear relationships were found to exist between total serum bilirubin concentration and yellowish skin color intensity in both term and low-birth-weight infants of Japanese ancestry. The instrument was examined for precision, accuracy, and technique-dependence. From these resulting relationships, it can be concluded that the transcutaneous bilirubin measurement is precise and accurate, and will become an alternative to the routine procedures used to measure serum bilirubin concentration in the near future. Although the values obtained during phototherapy or postexchange stage do not correlate well with serum bilirubin measurement, transcutaneous bilirubin will be accepted by the general nursery staffs because of its potential screening value.
Submitted on September 19, 1979
This article has been cited by other articles:
![]() |
H T Ho, T K Ng, K C Tsui, and Y C Lo Evaluation of a new transcutaneous bilirubinometer in Chinese newborns Arch. Dis. Child. Fetal Neonatal Ed., November 1, 2006; 91(6): F434 - F438. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Maisels Historical Perspectives: Transcutaneous Bilirubinometry NeoReviews, May 1, 2006; 7(5): e217 - e225. [Full Text] [PDF] |
||||
![]() |
K. Grohmann, M. Roser, B. Rolinski, I. Kadow, C. Muller, A. Goerlach-Graw, M. Nauck, and H. Kuster Bilirubin Measurement for Neonates: Comparison of 9 Frequently Used Methods Pediatrics, April 1, 2006; 117(4): 1174 - 1183. [Abstract] [Full Text] [PDF] |
||||
![]() |
C M Wong, P J E van Dijk, and I A Laing A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta AirShields Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2002; 87(2): F137 - 140. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. D. Engle, G. L. Jackson, D. Sendelbach, D. Manning, and W. H. Frawley Assessment of a Transcutaneous Device in the Evaluation of Neonatal Hyperbilirubinemia in a Primarily Hispanic Population Pediatrics, July 1, 2002; 110(1): 61 - 67. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. F. Rubaltelli, G. R. Gourley, N. Loskamp, N. Modi, M. Roth-Kleiner, A. Sender, and P. Vert Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device Pediatrics, June 1, 2001; 107(6): 1264 - 1271. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Madlon-Kay Home Health Nurse Clinical Assessment of Neonatal Jaundice: Comparison of 3 Methods Arch Pediatr Adolesc Med, May 1, 2001; 155(5): 583 - 586. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J. Madlon-Kay Recognition of the Presence and Severity of Newborn Jaundice by Parents, Nurses, Physicians, and Icterometer Pediatrics, September 1, 1997; 100(3): e3 - e3. [Abstract] [Full Text] [PDF] |
||||