PEDIATRICS Vol. 64 No. 6 December 1979, pp. 892-897
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Löfgren, O.
Right arrow Articles by Jacobson, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Löfgren, O.
Right arrow Articles by Jacobson, L.

The Influence of Different Electrode Temperatures on the Recorded Transcutaneous Po2 Level

O. Löfgren MD1 and L. Jacobson MD1

1 Department of Obstetrics and Gynecology, University of Lund, General Hospital, Malmö, Sweden

The technique of transcutaneous monitoring of oxygen partial pressure (Ptco2,), first described in 1969, provided a new clinical possibility for continuous and noninvasive surveillance of changes in the oxygenation of the organism. To obtain optimal arterialization of the skin and thus a reliable recording, the electrodes used have been supplied with microheating elements. The electrode temperature used implies the risk of producing burns; this is especially true when the measurements are performed in patients with decreased skin circulation or in immature children with a thin and vulnerable skin. Thus, a careful choice of the electrode temperature is important in PtcO2 recording; a higher temperature is desirable for obtaining adequate arterialization, whereas a lower temperature is preferred for reducing the risk of burns. The electrode temperatures described for PtcO2 measurements range from 42-45 C. A systematic study with the Radiometer TCM 1 equipment showed that changing the electrode temperature influences the PtcO2 in a systematic way within the temperature range 43.0-45.0 C. The study also showed that simultaneous measurements obtained from two electrodes with different temperatures showed a highly parallel course and a comparable oscillating pattern within this temperature range. The results of the present study suggest that an electrode temperature of 44.5 C may be the most appropriate for this equipment in clinical applications with newborns.

Submitted on November 27, 1978
Accepted on March 7, 1979




This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
A Carmichael, S McCullough, and S T Kempley
Critical dependence of acetate thermal mattress on gel activation temperature
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2007; 92(1): F44 - F45.
[Abstract] [Full Text] [PDF]