PEDIATRICS Vol. 62 No. 5 November 1978, pp. 692-697
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by le Souëf, P. N.
Right arrow Articles by Parker, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by le Souëf, P. N.
Right arrow Articles by Parker, D.

Comparison of Transcutaneous Oxygen Tension With Arterial Oxygen Tension in Newborn Infants With Severe Respiratory Illnesses

Peter N. le Souëf M.R.C.P.1, Andrew K. Morgan B.Sc.1, Linda P. Soutter Ph.D.2, E. Osmund R. Reynolds F.R.C.P.2, and Dawood Parker Ph.D.2

1 Departments of Puediatrics Medical Physics and Bioengineering, University College Hospital and Medical School, London
2 Departments of Paediatrics and Medical Physics and Bioengineering, University College Hospital and Medical School, London

Transcutaneous oxygen tesion (tcPO2), measured by two skin electrodes of different design, and arterial oxygen tension (PaO2), measured by an intravascular oxygen electrode, were continuously recorded for periods of six hours in 15 newborn infants with serious respiratory illnesses. Ten of the infants needed mechanical ventilation and three needed continuous positive airway pressure. One skin electrode had three microcathodes surrounded by a heated ring-shaped anode, and the other had a large heated cathode. The temperature of both electrodes was set at 44°C and they were calibrated in vitro.

The tcPO2 recorded by the electrode with the microcathodes was found to estimate PaO2 reasonably accurately for the whole six-hour duration of the study. The tcPO2 recorded by the electrode with the large cathode gave a similar estimate of PaO2. for three hours, but then tcPO2. often fell relative to PaO2. This fall was probably caused by skin changes at the electrode site.

For a variety of reasons, our results suggest that measurement of tcPO2. is unlikely to replace continuous intravascular measurement of PaO2. in infants with severe respiratory illnesses.

Submitted on January 17, 1978
Accepted on April 12, 1978




This article has been cited by other articles:


Home page
PediatricsHome page
R. T. Hall
Indications for Surfactant Therapy---The aAPO2 Coming of Age
Pediatrics, February 1, 1999; 103(2): 25e - 25.
[Abstract] [Full Text]