1 Department of Paediatrics and Neonatal Medicine, Hammersmith Hospital, London, England
Lung volume, airway resistance, and compliance have been measured in 19 infants, 18 of whom suffered from the respiratory distress syndrome (RDS) at birth, while the remaining infant was ventilated for persistent apnea and a pneumothorax. Prior to discharge from the neonatal unit, and after recovery from RDS, most infants were found to have essentially normal lung function. When retested between 4 and 11 months of age, every infant who had received artificial ventilation during the acute illness was found to have developed a raised airway resistance, whereas the remaining infants, who had been treated with continuous positive airway pressure and/or oxygen were all entirely normal. The implications of these results for the management of RDS are discussed.
Submitted on March 27, 1975
This article has been cited by other articles:
![]() |
R. Hamutcu, T. A. Nield, M. Garg, T. G. Keens, and A. C.G. Platzker Long-Term Pulmonary Sequelae in Children Who Were Treated With Extracorporeal Membrane Oxygenation for Neonatal Respiratory Failure Pediatrics, November 1, 2004; 114(5): 1292 - 1296. [Abstract] [Full Text] [PDF] |
||||
![]() |
E Eber and M S Zach Paediatric origins of adult lung disease {bullet} 8: Long term sequelae of bronchopulmonary dysplasia (chronic lung disease of infancy) Thorax, April 1, 2001; 56(4): 317 - 323. [Full Text] |
||||
![]() |
C. BEARDSMORE, I. DUNDAS, K. POOLE, K. ENOCK, and J. STOCKS Respiratory Function in Survivors of the United Kingdom Extracorporeal Membrane Oxygenation Trial Am. J. Respir. Crit. Care Med., April 1, 2000; 161(4): 1129 - 1135. [Abstract] [Full Text] |
||||
![]() |
J. Stocks Assessment of lung function in infants Perfusion, January 1, 1993; 8(1): 71 - 80. [PDF] |
||||