PEDIATRICS Vol. 24 No. 5 November 1959, pp. 814-818
This Article
Right arrow Full Text (PDF)
Right arrow P3Rs: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when P3Rs are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goldman, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Goldman, A. S.

A SIMPLE RAPID METHOD FOR DETERMINATION OF SPECIFIC GRAVITY OF SMALL SAMPLES OF URINE

Allen S. Goldman M.D.1

1 Department of Pediatrics, Yale University School of Medicine, and the Grace-New Haven Community Hospital

THE THERAPY of infants with disturbances in fluid balance is greatly assisted by knowledge of the specific gravity of the urine. Frequently only a few milliliters can be collected at any one time, while a minimum sample of 25 ml is necessary for use of the smallest urinometers currently available. The existing methods of determining specific gravity of one drop of urine are somewhat laborious, and require expensive equipment and the services of a relatively skilled technician.

The present report describes a method which is rapid and simple and requires only a few drops of urine in its use. It is similar in principle to the determination of specific gravity of blood by the copper-sulfate method. For use with urine, mixtures are employed of two relatively nonvolatile liquids, immiscible with water, and with specific gravities nearly equally above and below the range in urine. The specific gravity of urine is determined by allowing one drop to fall into each of a series of tubes containing a mixture of the two liqquids made up to various specific gravities ranging from 1.005 to 1.030 (Fig. 1). That mixture in which the drop of urine comes most nearly to remaining still (neither rising nor falling after coming to rest) approximates the specific gravity of the urine. The total sample needed is only a few drops, which can be quite small if a dropper with a small opening (2 mm) is used. The determination takes a few minutes. A year's supply of the mixtures can be made in one afternoon and costs less than $6.00.

MATERIALS

The two solutions used were selected from the flotation method of Kirk, using a density gradient system. These are Liquid 1, dibutyl-n-phthalate (Eastman), specific gravity 1.04820°; and Liquid 2, kerosene, specific gravity 0.8220°. (Similar results were obtained by substituting California mineral oil, specific gravity 0.842-0.88420°, for kerosene.)