Published online July 20, 2009
PEDIATRICS Vol. 124 No. 2 August 2009, pp. e339-e346 (doi:10.1542/peds.2008-3653)
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via CrossRef
Google Scholar
Right arrow Articles by Vanderhal, A. L.
Right arrow Articles by Hagiike, M.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vanderhal, A. L.
Right arrow Articles by Hagiike, M.
Related Collections
Right arrow Premature & Newborn
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

ARTICLE

A Videolaryngoscopy Technique for the Intubation of the Newborn: Preliminary Report

Andre L. Vanderhal, MDa, George Berci, MDb, Charles F. Simmons, Jr, MDa and Masanobu Hagiike, MDb

a Department of Pediatrics, Division of Neonatology
b Department of Surgery, Minimally Invasive Surgery Research, Cedars-Sinai Medical Center, Los Angeles, California

OBJECTIVE: We describe videolaryngoscopy equipment and technique for endotracheal intubation and airway evaluation in the delivery room (DR) and NICU for endotracheal intubation and airway evaluation. We report our first experience of 47 patients.

METHODS: Forty-seven infants who weighed 530 to 6795 g and required endotracheal intubation or airway evaluation were considered for intubation or assessment by using the modified Kaplan-Berci videolaryngoscope. We report quality-improvement data after initial introduction of newly approved technology.

RESULTS: We report results of 48 intubations in 42 patients and videolaryngoscopic inspection without intubation in 5 patients. Five intubation attempts were successful after failed attempts by experienced intubators; 6 attempts by residents were completed with video guidance rather than requiring an additional attempt. Only 3 intubations required more than 2 attempts. Enlarged panoramic view and recording assisted in correct diagnosis of vocal cord paralysis. The features and main advantages are discussed in detail. No complications or difficulties resulting from the technology occurred.

CONCLUSIONS: This new technique and technology show promise to improve airway management, evaluation, and teaching. Future research to validate improved intubation success in difficult airways and in teaching situations is warranted.


Key Words: videolaryngoscope • newborn • pediatric airway management • difficult airway • intubation technique

Abbreviations: ETT—endotracheal tube • DR—delivery room


Accepted Mar 27, 2009.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?