PEDIATRICS Vol. 118 No. 4 October 2006, pp. 1574-1582 (doi:10.1542/peds.2005-0413)
ARTICLE |
Achieved Versus Intended Pulse Oximeter Saturation in Infants Born Less Than 28 Weeks' Gestation: The AVIOx Study
a Division of Neonatology, Connecticut Children's Medical Center, Hartford, Connecticut
b Division of Newborn Medicine, Floating Hospital for Children/Tufts-New England Medical Center, Boston, Massachusetts
c Division of Neonatology, Children's Hospital Boston, Boston, Massachusetts
d Institute for Clinical Research and Health Policy Studies, Tufts-New England Medical Center, Boston, Massachusetts
e Departments of Pediatrics and Ophthalmology, University of Rochester School of Medicine and Dentistry, Rochester, New York
f Departments of Pediatrics, Ophthalmology, and Molecular & Medical Genetics, Doernbecher Children's Hospital, Casey Eye Institute, Oregon Health & Science University, Portland, Oregon
g Department of Neonatology, Beth Israel-Deaconess Medical Center, Boston, Massachusetts
OBJECTIVE. The objective of this study was to document pulse oximeter saturation levels achieved in the first 4 weeks of life in infants who were born at <28 weeks' gestation, compared with the levels that were targeted by local policy, and examine factors that are associated with compliance with the target range.
METHODS. Infants who were <28 weeks' gestation and
96 hours of age were enrolled in a prospective, multicenter cohort study. Oximetry data were collected with masked signal-extraction oximeters for a 72-hour period in each of the first 4 weeks of life. Data were compared with the pulse oximeter saturation target range prescribed by local institutional policy. Factors that were associated with intended range compliance were identified with hierarchical modeling.
RESULTS. Fourteen centers from 3 countries enrolled 84 infants with mean ± SD birth weight of 863 ± 208 g and gestational age of 26 ± 1.4 weeks. Oxygen saturation policy limits ranged between 83% and 92% for lower limits and 92% and 98% for upper limits. For infants who received respiratory support, median pulse oximeter saturation level achieved was 95%. Center-specific medial levels were within the intended range at 12 centers. Centers maintained infants within their intended range 16% to 64% of the time but were above range 20% to 73% of the time. In hierarchical modeling, wider target ranges, higher target range upper limits, presence of a policy of setting oximeter alarms close to the target range limits, and lower gestational age were associated with improved target range compliance.
CONCLUSIONS. Success with maintaining the intended pulse oximeter saturation range varied substantially among centers, among patients within centers, and for individual patients over time. Most noncompliance was above the intended range. Methods for improving compliance and the effect of improved compliance on neonatal outcomes require additional research.
Key Words: prematurity oximetry oxygen saturation policies neonatal
Abbreviations: ROPretinopathy of prematurity BPDbronchopulmonary dysplasia SpO2pulse oximeter saturation SETSignal Extraction Technology SNAP-II scoreScore for Neonatal Acute Physiology, Version II FIO2fraction of inspired oxygen IQRinterquartile range CIconfidence interval
Accepted May 31, 2006.
![]()
CiteULike
Connotea
Del.icio.us
Digg
Facebook
Reddit
Technorati
Twitter What's this?
This article has been cited by other articles:
![]() |
A. Bhandari and V. Bhandari Pitfalls, Problems, and Progress in Bronchopulmonary Dysplasia Pediatrics, June 1, 2009; 123(6): 1562 - 1573. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Castillo, A. Sola, H. Baquero, F. Neira, R. Alvis, R. Deulofeut, and A. Critz Pulse Oxygen Saturation Levels and Arterial Oxygen Tension Values in Newborns Receiving Oxygen Therapy in the Neonatal Intensive Care Unit: Is 85% to 93% an Acceptable Range? Pediatrics, May 1, 2008; 121(5): 882 - 889. [Abstract] [Full Text] [PDF] |
||||
![]() |
T.-H. Nghiem, J. I. Hagadorn, N. Terrin, S. Syke, B. MacKinnon, and C. H. Cole Nurse Opinions and Pulse Oximeter Saturation Target Limits for Preterm Infants Pediatrics, May 1, 2008; 121(5): e1039 - e1046. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Claure Automated Regulation of Inspired Oxygen in Preterm Infants: Oxygenation Stability and Clinician Workload Anesth. Analg., December 1, 2007; 105(6S_Suppl): S37 - S41. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Clucas, L. W. Doyle, J. Dawson, S. Donath, and P. G. Davis Compliance With Alarm Limits for Pulse Oximetry in Very Preterm Infants Pediatrics, June 1, 2007; 119(6): 1056 - 1060. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. P. Goldsmith and J. S. Greenspan Neonatal Intensive Care Unit Oxygen Management: A Team Effort Pediatrics, June 1, 2007; 119(6): 1195 - 1196. [Full Text] [PDF] |
||||
![]() |
J. S. Greenspan and J. P. Goldsmith Oxygen Therapy in Preterm Infants: Hitting the Target Pediatrics, October 1, 2006; 118(4): 1740 - 1741. [Full Text] [PDF] |
||||






