PEDIATRICS Vol. 117 No. 2 February 2006, pp. e164-e175 (doi:10.1542/peds.2005-0936)
A Survey of Delivery Room Resuscitation Practices in the United States
Department of Pediatrics, Division of Neonatology, University of California, San Diego, San Diego, California
Objective. To determine current resuscitation practices of neonatologists in the United States.
METHODS. A 15-question survey was developed and mailed to neonatal directors in May 2004.
ELRESULTS. Of the total of 797 surveys mailed, 84 were returned undeliverable or unanswered and 450 were returned completed (63% response rate). Respondents were mainly (70%) from level III NICUs. Most programs resuscitate newborns in the delivery room (83%), rather than in a separate room. The number and background of individuals attending deliveries vary greatly, with 31% of programs having <3 individuals attending deliveries. Flow-inflating bags are most commonly used (51%), followed by self-inflating bags (40%) and T-piece resuscitators (14%). Pulse oximeters are used during resuscitation by 52% of programs, and 23% of respondents indicated that there was a useful signal within 1 minute after application. Blenders are available for 42% of programs, of which 77% use pure oxygen for the initial resuscitation and 68% use oximeters to alter the fraction of inspired oxygen. Thirty-two percent of programs use carbon dioxide detectors to confirm intubation, 48% routinely and 43% when there is difficulty confirming intubation. Preterm infants are wrapped with plastic wrap to prevent heat loss in 29% of programs, of which 77% dry the infant before wrap application. A majority of programs (76%) attempt to provide continuous positive airway pressure or positive end expiratory pressure (PEEP) during resuscitation, most commonly with a flow-inflating bag (58%), followed by a self-inflating bag with PEEP valve (19%) and T-piece resuscitator (16%). A level of 5 cm H2O is used by 55% of programs.
CONCLUSIONS. Substantial variations exist in neonatal resuscitation practices, some of which are not addressed in standard guidelines. Future guidelines should include recommendations regarding the use of blenders, oximeters, continuous positive airway pressure/PEEP, and plastic wrap during resuscitation.
Key Words: neonatal resuscitation survey practice variation delivery room
Abbreviations: NRPNeonatal Resuscitation Program PEEPpositive end expiratory pressure CPAPcontinuous positive airway pressure PPVpositive pressure ventilation ELBWextremely low birth weight
Accepted Jul 29, 2005.
![]()
CiteULike
Connotea
Del.icio.us
Digg
Facebook
Reddit
Technorati
Twitter What's this?
This article has been cited by other articles:
![]() |
M. Thio, R. Bhatia, J. A. Dawson, and P. G. Davis Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2010; 95(5): F315 - F319. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. R. Wauer, C. C. Roehr, and for the Scientific Committee International Perspectives: Report on the International Seminar on Surfactant and CPAP in Extremely Low Gestational Age Neonates, Vienna 2009 NeoReviews, July 1, 2010; 11(7): e343 - e348. [Full Text] [PDF] |
||||
![]() |
G. M. Schmolzer, O. C. O. F. Kamlin, J. A. Dawson, A. B. te Pas, C. J. Morley, and P. G. Davis Respiratory monitoring of neonatal resuscitation Arch. Dis. Child. Fetal Neonatal Ed., July 1, 2010; 95(4): F295 - F303. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Schmolzer, O. C. O. F. Kamlin, C. P. F. O'Donnell, J. A. Dawson, C. J. Morley, and P. G. Davis Assessment of tidal volume and gas leak during mask ventilation of preterm infants in the delivery room Arch. Dis. Child. Fetal Neonatal Ed., June 14, 2010; (2010) adc.2009.174003v1. [Abstract] [Full Text] |
||||
![]() |
J. Dawson, C. Kamlin, C. Wong, A. te Pas, M. Vento, T. Cole, S. Donath, S. Hooper, P. Davis, and C. Morley Changes in heart rate in the first minutes after birth Arch. Dis. Child. Fetal Neonatal Ed., May 1, 2010; 95(3): F177 - F181. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. E Wood, C. J Morley, J. A Dawson, C O. F Kamlin, L. S Owen, S. Donath, and P. G Davis Improved techniques reduce face mask leak during simulated neonatal resuscitation: study 2 Arch. Dis. Child. Fetal Neonatal Ed., May 1, 2008; 93(3): F230 - F234. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Kemp Resuscitation practices vary among U.S. neonatologists AAP News, March 1, 2006; 27(3): 2 - 2. [Full Text] |
||||







