Ultrasound Imaging of Milk Ejection in the Breast of Lactating Women

* Department of Biochemistry and Molecular Biology, School of Biomedical and Chemical Sciences, Faculty of Life and Physical Sciences
School of Computer Science and Software Engineering, Faculty of Engineering, Computing and Mathematics, University of Western Australia, Crawley WA 6009, Australia
Objective. Currently, the methods for assessing milk ejection in women include serial sampling of plasma oxytocin and measurement of intraductal pressure, both of which are invasive and may induce stress. We hypothesized that milk ejection would cause an increase in milk-duct diameter that could be observed noninvasively with ultrasound, and this could be used to investigate the physiology of milk ejection in women.
Methods. One milk duct was scanned in the unsuckled breast in 2 groups of mothers: group BB (n = 21) for the beginning of a breastfeed and group EB (n = 24) for the entire breastfeed. A duct also was monitored for a 5-minute period on 2 separate days in the absence of factors that may induce milk ejection in group EB to provide a baseline duct diameter. Milk intake at a breastfeed was measured by test weighing.
Results. A significant increase in milk-duct diameter was observed when milk ejection was sensed and/or the infant changed its swallowing pattern in both groups. Multiple increases and decreases (mean: 2.5 per breastfeed; standard deviation: 1.5; n = 62) in duct diameter occurred in group EB. Duct diameter remained relatively stable between breastfeeds (coefficient of variation: 1.4%8.3%). Infant milk intake was positively related to the number of milk ejections (r2 = .365; n = 57).
Conclusions. Ultrasound is an objective, noninvasive technique for detecting milk ejection by observing an increase in milk-duct diameter. However, this technique requires an experienced ultrasonographer, adequate imaging time, and surroundings conducive to breastfeeding. Multiple milk ejections were common during breastfeeding, although they were not sensed by mothers. The number of milk ejections influenced the amount of milk the infant consumed.
Key Words: milk ejection ultrasound milk duct breast
Abbreviations: BB, beginning of breastfeed EB, entire breastfeed CV, coefficient of variation SD, standard deviation
Received for publication Jun 4, 2003; Accepted Oct 13, 2003.
![]()
CiteULike
Connotea
Del.icio.us
Digg
Facebook
Reddit
Technorati
Twitter What's this?
This article has been cited by other articles:
![]() |
L. Densmore and S. M. V. Pflueger Using Interphase Fluorescence In Situ Hybridization (I-FISH) to Detect the Transfer of Infant Cells During Breastfeeding J Hum Lact, November 1, 2008; 24(4): 401 - 405. [Abstract] [PDF] |
||||
![]() |
K. Ogawa, T. Kusaka, K. Tanimoto, T. Nishida, K. Isobe, and S. Itoh Changes in Breast Hemodynamics in Breastfeeding Mothers J Hum Lact, November 1, 2008; 24(4): 415 - 421. [Abstract] [PDF] |
||||
![]() |
B. Wilson-Clay Case Report of Methicillin-Resistant Staphylococcus aureus (MRSA) Mastitis With Abscess Formation in a Breastfeeding Woman J Hum Lact, August 1, 2008; 24(3): 326 - 329. [Abstract] [PDF] |
||||
![]() |
A. K. Spangler, A. L. Randenberg, M. G. Brenner, and M. Howett Belly Models as Teaching Tools: What Is Their Utility? J Hum Lact, May 1, 2008; 24(2): 199 - 205. [Abstract] [PDF] |
||||
![]() |
C A Walshaw, J M Owens, A J Scally, and M J Walshaw Does breastfeeding method influence infant weight gain? Arch. Dis. Child., April 1, 2008; 93(4): 292 - 296. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. P. Meier and J. L. Engstrom Evidence-based Practices to Promote Exclusive Feeding of Human Milk in Very Low-birthweight Infants NeoReviews, November 1, 2007; 8(11): e467 - e477. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Sabate, M. Clotet, S. Torrubia, A. Gomez, R. Guerrero, P. de Las Heras, and E. Lerma Radiologic Evaluation of Breast Disorders Related to Pregnancy and Lactation RadioGraphics, October 1, 2007; 27(suppl_1): S101 - S124. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. A. Jacobs, J. E. Dickinson, P. D. Hart, D. A. Doherty, and S. J. Faulkner Normal Nipple Position in Term Infants Measured on Breastfeeding Ultrasound J Hum Lact, February 1, 2007; 23(1): 52 - 59. [Abstract] [PDF] |
||||
![]() |
S. A. Lederman, J. Hopkinson, S. R. Geraghty, J. C. Khoury, H. J. Kalkwarf, C A Walshaw, D. G. (Ramsay), B. Wilson-Clay, K. Hoover, J. Hopkinson, et al. Letters to the Editor J Hum Lact, November 1, 2006; 22(4): 387 - 390. [PDF] |
||||
![]() |
D. T. Ramsay, L. R. Mitoulas, J. C. Kent, M. Larsson, and P. E. Hartmann The Use of Ultrasound to Characterize Milk Ejection in Women Using an Electric Breast Pump J Hum Lact, November 1, 2005; 21(4): 421 - 428. [Abstract] [PDF] |
||||