This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Claure, N.
Right arrow Articles by Bancalari, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Claure, N.
Right arrow Articles by Bancalari, E.
Related Collections
Right arrow Premature & Newborn
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

PEDIATRICS Vol. 107 No. 5 May 2001, pp. 1120-1124

Closed-Loop Controlled Inspired Oxygen Concentration for Mechanically Ventilated Very Low Birth Weight Infants With Frequent Episodes of Hypoxemia

Received Apr 18, 2000; accepted Nov 22, 2000.

Nelson Claure, Tilo Gerhardt, Ruth Everett, Gabriel Musante, Carmen Herrera, and Eduardo Bancalari

From the Division of Neonatology, Department of Pediatrics, University of Miami School of Medicine, Miami, Florida.

Background.  Mechanically ventilated very low birth weight infants often present with frequent episodes of hypoxemia, and maintaining arterial oxygen saturation by pulse oximetry (SpO2) within a normal range by manual fraction of inspired oxygen (FIO2) adjustments is difficult and time consuming.

Objectives.  An algorithm for closed-loop FIO2 control (cFIO2) to maintain SpO2 within a target range was compared with continuous manual FIO2 (mFIO2) adjustments by a nurse in a group of ventilated infants who presented with frequent episodes of hypoxemia.

Results.  Fourteen infants (birth weight: 712 ± 142 g; gestational age: 25 ± 1.6 weeks; age: 26 ± 11 days; synchronized intermittent mandatory ventilation rate: 24 ± 10 b/m; peak inspiratory pressure: 17.5 ± 2.0 cmH2O; positive end-expiratory pressure: 4.3 ± 0.5 cmH2O) were studied for 2 hours on each mode in random sequence. Both modes aimed to maintain SpO2 between 88% and 96%. There were 15 ± 7 and 16 ± 6 hypoxemic episodes/hour (SpO2 <88%, >5 s) during mFIO2 and cFIO2, respectively; episode duration was 41 ± 23 and 32 ± 15 s, totaling 19 ± 16% and 17 ± 12% of recording time. There were 13 ± 10 and 10 ± 8 hyperoxemic episodes/hour (SpO2>96%, >5 s) during mFIO2 and cFIO2, respectively; episode duration was 27 ± 15 and 24 ± 19 s, totaling 15 ± 14% and 10 ± 9% of recording time. Mean SpO2 and FIO2 levels were similar during both modes. The nurse made 29 ± 17 adjustments/hour during mFIO2. There was a significant increase in the duration of normoxemia (SpO2 between 88%-96%) during cFIO2 (75 ± 13 vs 66 ± 14% of recording time).

Conclusion.  In this group of infants, cFIO2 was at least as effective as a fully dedicated nurse in maintaining SpO2 within the target range, and it may be more effective than a nurse working under routine conditions. We speculate that during long-term use, cFIO2 may save nursing time and reduce the risks of morbidity associated with supplemental oxygen and episodes of hypo- and hyperoxemia.  Key words:  hypoxemic episodes, preterm infant, mechanical ventilation, FIO2, automatic FIO2 adjustment, closed-loop FIO2 control.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
A Balaguer, R Quiroga-Gonzalez, M Camprubi, M Mila-Farnes, J Escribano, and M Girabent-Farres
Reducing errors in the management of hyperbilirubinaemia: validating a software application
Arch. Dis. Child. Fetal Neonatal Ed., January 1, 2009; 94(1): F45 - F47.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child. Fetal Neonatal Ed.Home page
C. F Poets and D. Bassler
Providing stability in oxygenation for preterm infants: is transcutaneous oxygen monitoring really better than pulse oximetry?
Arch. Dis. Child. Fetal Neonatal Ed., September 1, 2008; 93(5): F330 - F331.
[Full Text] [PDF]


Home page
PediatricsHome page
T.-H. Nghiem, J. I. Hagadorn, N. Terrin, S. Syke, B. MacKinnon, and C. H. Cole
Nurse Opinions and Pulse Oximeter Saturation Target Limits for Preterm Infants
Pediatrics, May 1, 2008; 121(5): e1039 - e1046.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
D. Xu, R. E. Perez, I. I. Ekekezie, A. Navarro, and W. E. Truog
Epidermal growth factor-like domain 7 protects endothelial cells from hyperoxia-induced cell death
Am J Physiol Lung Cell Mol Physiol, January 1, 2008; 294(1): L17 - L23.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
N. Claure
Automated Regulation of Inspired Oxygen in Preterm Infants: Oxygenation Stability and Clinician Workload
Anesth. Analg., December 1, 2007; 105(6S_Suppl): S37 - S41.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
J. I. Hagadorn, A. M. Furey, T.-H. Nghiem, C. H. Schmid, D. L. Phelps, D.-A. M. Pillers, C. H. Cole, and and the AVIOx Study Group
Achieved Versus Intended Pulse Oximeter Saturation in Infants Born Less Than 28 Weeks' Gestation: The AVIOx Study
Pediatrics, October 1, 2006; 118(4): 1574 - 1582.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
J. S. Greenspan and J. P. Goldsmith
Oxygen Therapy in Preterm Infants: Hitting the Target
Pediatrics, October 1, 2006; 118(4): 1740 - 1741.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. S. Urschitz, W. Horn, A. Seyfang, A. Hallenberger, T. Herberts, S. Miksch, C. Popow, I. Muller-Hansen, and C. F. Poets
Automatic Control of the Inspired Oxygen Fraction in Preterm Infants: A Randomized Crossover Trial
Am. J. Respir. Crit. Care Med., November 15, 2004; 170(10): 1095 - 1100.
[Abstract] [Full Text] [PDF]