This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow E-mail this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My File Cabinet
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via CrossRef
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chase, H. P.
Right arrow Articles by Garg, S. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chase, H. P.
Right arrow Articles by Garg, S. K.
Related Collections
Right arrow Endocrinology
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Facebook   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

PEDIATRICS Vol. 107 No. 2 February 2001, pp. 222-226

Continuous Subcutaneous Glucose Monitoring in Children With Type 1 Diabetes

Received Sep 26, 2000; accepted Nov 13, 2000.

H. Peter Chase*, Laura M. Kim*, Susie L. Owen*, Todd A. MacKenzieDagger , Georgeanna J. Klingensmith*, Robert Murtfeldt§, and Satish K. Garg*

From the * Department of Pediatrics, Barbara Davis Center for Childhood Diabetes, Denver, Colorado; Dagger  Preventive Medicine and Biometrics, University of Colorado Health Sciences Center, Denver, Colorado; and § MiniMed, Sylmar, California.

Purpose.  To determine whether the use of continuous subcutaneous glucose monitoring will help in detecting unrecognized nocturnal hypoglycemia and in lowering hemoglobin A1c (HbA1c) levels (without increasing the risk for severe hypoglycemia) in children with type 1 diabetes.

Methods.  Eleven children with type 1 diabetes and HbA1c values consistently >8.0% were randomized either to the Continuous Glucose Monitoring System (CGMS) group or to the control group. The CGMS group used 6 3-day sensors within a 30-day period. Both groups self-monitored their blood glucose levels a minimum of 4 times daily. HbA1c levels were measured at the start, at 1-month, and after 3 months of study.

Results.  The 5 children using the CGMS had 17 asymptomatic episodes (85%) of glucose levels below 60 mg/dL (3.25 mmol/L) and 3 symptomatic episodes (15%) during the night in the study month. The 6 control children had 4 symptomatic nocturnal low episodes during the month. After the 30-day period of wearing the CGMS, the 5 children had a significantly lower mean HbA1c value compared with their initial value (mean ± standard error of the mean [SEM] decrease = .36% ± .07%). The mean decrease for the controls was .2% ± .2%. After 3 months, 4 of the 5 children who used the CGMS continued to have lower HbA1c values in comparison to their initial values (mean ± SEM decrease = 1.04% ± .43%). Three of the 6 control participants also had lower HbA1c values at 3 months (mean ± SEM decrease for the group = .62% ± .44%). No severe hypoglycemic events occurred in either the CGMS or the control groups.

Conclusion.  In this pilot trial, continuous subcutaneous glucose monitoring was helpful in detecting asymptomatic nocturnal hypoglycemia as well as in lowering HbA1c values without increasing the risk for severe hypoglycemia in children with type 1 diabetes.  Key words:  continuous glucose monitoring.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Facebook Facebook   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Diabetes Spectr.Home page
M. R. Burge, S. Mitchell, A. Sawyer, and D. S. Schade
Continuous Glucose Monitoring: The Future of Diabetes Management
Diabetes Spectr, April 1, 2008; 21(2): 112 - 119.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. K. Garg, W. C. Kelly, M. K. Voelmle, P. J. Ritchie, P. A. Gottlieb, K. K. McFann, and S. L. Ellis
Continuous Home Monitoring of Glucose: Improved glycemic control with real-life use of continuous glucose sensors in adult subjects with type 1 diabetes
Diabetes Care, December 1, 2007; 30(12): 3023 - 3025.
[Full Text] [PDF]


Home page
Diabetes CareHome page
S. Garg and L. Jovanovic
Relationship of Fasting and Hourly Blood Glucose Levels to HbA1c Values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor
Diabetes Care, December 1, 2006; 29(12): 2644 - 2649.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. Deiss, J. Bolinder, J.-P. Riveline, T. Battelino, E. Bosi, N. Tubiana-Rufi, D. Kerr, and M. Phillip
Improved Glycemic Control in Poorly Controlled Patients with Type 1 Diabetes Using Real-Time Continuous Glucose Monitoring
Diabetes Care, December 1, 2006; 29(12): 2730 - 2732.
[Full Text] [PDF]


Home page
Diabetes CareHome page
K. M. Dungan, J. B. Buse, J. Largay, M. M. Kelly, E. A. Button, S. Kato, and S. Wittlin
1,5-Anhydroglucitol and Postprandial Hyperglycemia as Measured by Continuous Glucose Monitoring System in Moderately Controlled Patients With Diabetes.
Diabetes Care, June 1, 2006; 29(6): 1214 - 1219.
[Abstract] [Full Text] [PDF]


Home page
The Diabetes EducatorHome page
L. K. Fisher and M. Halvorson
Future Developments in Insulin Pump Therapy: Progression From Continuous Subcutaneous Insulin Infusion to a Sensor-Pump System
The Diabetes Educator, January 1, 2006; 32(1): 47S - 52S.
[Full Text] [PDF]


Home page
The Diabetes EducatorHome page
V. Valentine
Continuous Glucose Monitoring Has Left the Station: Are You Onboard?
The Diabetes Educator, September 1, 2005; 31(5): 649 - 662.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
G. Admon, Y. Weinstein, B. Falk, N. Weintrob, H. Benzaquen, R. Ofan, G. Fayman, L. Zigel, N. Constantini, and M. Phillip
Exercise With and Without an Insulin Pump Among Children and Adolescents With Type 1 Diabetes Mellitus
Pediatrics, September 1, 2005; 116(3): e348 - e355.
[Abstract] [Full Text] [PDF]


Home page
CLIN PEDIATRHome page
S. A. Weinzimer, E. A. Doyle, and W. V. Tamborlane Jr
Disease Management in the Young Diabetic Patient: Glucose Monitoring, Coping Skills, and Treatment Strategies
Clinical Pediatrics, June 1, 2005; 44(5): 393 - 403.
[Abstract] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
The Diabetes Research in Children Network (DirecNe
Eight-Point Glucose Testing Versus the Continuous Glucose Monitoring System in Evaluation of Glycemic Control in Type 1 Diabetes
J. Clin. Endocrinol. Metab., June 1, 2005; 90(6): 3387 - 3391.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. C. Klonoff
Continuous Glucose Monitoring: Roadmap for 21st century diabetes therapy
Diabetes Care, May 1, 2005; 28(5): 1231 - 1239.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
Z. Ahmed, C. H. Lockhart, M. Weiner, and G. Klingensmith
Advances in Diabetic Management: Implications for Anesthesia
Anesth. Analg., March 1, 2005; 100(3): 666 - 669.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
G. S. Jeha, L. P. Karaviti, B. Anderson, E. O'Brian Smith, S. Donaldson, T. S. McGirk, and M. W. Haymond
Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes
Diabetes Care, December 1, 2004; 27(12): 2881 - 2886.
[Abstract] [Full Text] [PDF]


Home page
Mayo Clin Proc.Home page
R. Tanenberg, B. Bode, W. Lane, C. Levetan, J. Mestman, A. P. Harmel, J. Tobian, T. Gross, and J. Mastrototaro
Use of the Continuous Glucose Monitoring System to Guide Therapy in Patients With Insulin-Treated Diabetes: A Randomized Controlled Trial
Mayo Clin. Proc., December 1, 2004; 79(12): 1521 - 1526.
[Abstract] [PDF]


Home page
Arch Pediatr Adolesc MedHome page
N. Weintrob, A. Schechter, H. Benzaquen, S. Shalitin, P. Lilos, A. Galatzer, and M. Phillip
Glycemic Patterns Detected by Continuous Subcutaneous Glucose Sensing in Children and Adolescents With Type 1 Diabetes Mellitus Treated by Multiple Daily Injections vs Continuous Subcutaneous Insulin Infusion
Arch Pediatr Adolesc Med, July 1, 2004; 158(7): 677 - 684.
[Abstract] [Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
A. L. Briggs and S. Cornell
Self-monitoring Blood Glucose (SMBG): Now and the Future
Journal of Pharmacy Practice, February 1, 2004; 17(1): 29 - 38.
[Abstract] [PDF]


Home page
Pediatr. Rev.Home page
F. R. Kaufman
Type 1 Diabetes Mellitus
Pediatr. Rev., September 1, 2003; 24(9): 291 - 300.
[Full Text] [PDF]


Home page
PediatricsHome page
J. Ludvigsson and R. Hanas
Continuous Subcutaneous Glucose Monitoring Improved Metabolic Control in Pediatric Patients With Type 1 Diabetes: A Controlled Crossover Study
Pediatrics, May 1, 2003; 111(5): 933 - 938.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
H. P. Chase, M. D. Roberts, C. Wightman, G. Klingensmith, S. K. Garg, M. Van Wyhe, S. Desai, W. Harper, M. Lopatin, M. Bartkowiak, et al.
Use of the GlucoWatch Biographer in Children With Type 1 Diabetes
Pediatrics, April 1, 2003; 111(4): 790 - 794.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. Guerci, M. Floriot, P. Bohme, D. Durain, M. Benichou, S. Jellimann, and P. Drouin
Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin Analogs
Diabetes Care, March 1, 2003; 26(3): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
R. Amin, K. Ross, C. L. Acerini, J. A. Edge, J. Warner, and D. B. Dunger
Hypoglycemia Prevalence in Prepubertal Children With Type 1 Diabetes on Standard Insulin Regimen: Use of Continuous Glucose Monitoring System
Diabetes Care, March 1, 2003; 26(3): 662 - 667.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
L. Kessler, R. Passemard, J. Oberholzer, P. Y. Benhamou, P. Bucher, C. Toso, P. Meyer, A. Penfornis, L. Badet, P. Wolf, et al.
Reduction of Blood Glucose Variability in Type 1 Diabetic Patients Treated By Pancreatic Islet Transplantation: Interest of continuous glucose monitoring
Diabetes Care, December 1, 2002; 25(12): 2256 - 2262.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. Salardi, S. Zucchini, R. Santoni, L. Ragni, S. Gualandi, A. Cicognani, and E. Cacciari
The Glucose Area Under the Profiles Obtained With Continuous Glucose Monitoring System Relationships With HbAlc in Pediatric Type 1 Diabetic Patients
Diabetes Care, October 1, 2002; 25(10): 1840 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
K. McGowan, W. Thomas, and A. Moran
Spurious Reporting of Nocturnal Hypoglycemia by CGMS in Patients With Tightly Controlled Type 1 Diabetes
Diabetes Care, September 1, 2002; 25(9): 1499 - 1503.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. R. Zavalkoff and C. Polychronakos
Evaluation of Conventional Blood Glucose Monitoring as an Indicator of Integrated Glucose Values Using a Continuous Subcutaneous Sensor
Diabetes Care, September 1, 2002; 25(9): 1603 - 1606.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
M. Metzger, G. Leibowitz, J. Wainstein, B. Glaser, and I. Raz
Reproducibility of Glucose Measurements Using the Glucose Sensor
Diabetes Care, July 1, 2002; 25(7): 1185 - 1191.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
T. P. Monsod, D. E. Flanagan, F. Rife, R. Saenz, S. Caprio, R. S. Sherwin, and W. V. Tamborlane
Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?
Diabetes Care, May 1, 2002; 25(5): 889 - 893.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
F. R. Kaufman, L. C. Gibson, M. Halvorson, S. Carpenter, L. K. Fisher, and P. Pitukcheewanont
A Pilot Study of the Continuous Glucose Monitoring System: Clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects
Diabetes Care, December 1, 2001; 24(12): 2030 - 2034.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
E. Boland, T. Monsod, M. Delucia, C. A. Brandt, S. Fernando, and W. V. Tamborlane
Limitations of Conventional Methods of Self-Monitoring of Blood Glucose: Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes
Diabetes Care, November 1, 2001; 24(11): 1858 - 1862.
[Abstract] [Full Text] [PDF]